The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper presents a method to analyze and design the safe control system using the safety function. The safety function is defined to represent a safety domain in the state space. Using a model of controlled plant and a number of control logic examples with appropriate predetermined safety function, we can evaluate whether the whole system is safe or not. Illustrative example shows that the proposed...
This paper provides an approach of safety verification of logic control system with application of Gröbner bases method. We propose a method to analyze and design a safe control system using a safety function. In this case, the safety is defined to represent a safety domain in the state space. Using a plant model and controller examples with appropriate predetermined safety function, we can evaluate...