The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
In order to decrease the cost and allow the Permanent-magnet synchronous motor (PMSM) control system to continue operating under faulty conditions, the development of fault-tolerant control becomes especially important [1]-[4]. In general, when the fault occurs, the fault-tolerant control can be implemented by the real-time and effective detection, localization, and isolation for faulty switches,...
This paper proposes a technique able to detect and isolate multiple open-circuit faults of power switches in an MMC. Based on a sliding mode observer (SMO), the basic idea of this FDI method is to compare the observed states with the measured states. The fault occurrence is detected when the difference between the observed and measured arm current is larger than a threshold value; while a cell is...