The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper compares the radial vibration forces in 10-pole/12-slot fractional-slot SPM and IPM machines which are designed to produce the same output torque, and employ an identical stator but different SPM, V-shape and arc-shape IPM rotor topologies. The airgap field and radial vibration force density distribution as a function of angular position and corresponding space harmonics (vibration modes)...
This work presents an accurate and detailed analysis of the magnetic radial force density of a PM machine with 12-teeth/10-poles winding topology. The air-gap radial force density distribution of the studied PM machine, as function of angular position and corresponding space harmonics (modes) is analysed using a combination of finite elements (FE) and analytical methods. It is shown that, due to the...