The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Laboratory-based accelerated thermal ageing experiments were conducted in order to compare the performance of oils before and after being subject to oil regeneration. Three commercially available new mineral oils were used as a benchmark for the performance of the regenerated oil. Samples consisting of oil, paper and copper were aged at 120 °C under sealed conditions for a period of up to 63 days...
Insulating system of power transformers is mostly composed of two basic components: insulation oil and cellulose paper (oil-paper system). These components are of an organic nature and thatpsilas why they become very sensitive to operation degradation conditions (temperature, oxidation, moisture etc.). Aging of these components can endanger the failure free operation of the transformers. The main...