The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
For more than a century, conventional mineral oil/cellulose insulation is being used as main insulation for power transformers. The life span of these major assets is determined amongst others by the insulation system’s mechanical resistance to withstand short circuit current forces. Since cellulose paper aging is accelerated by temperature, moisture and oxygen, poly-aramid-based synthetic insulation...
This paper is aimed at evaluation about aging properties of cellulose paper used for insulating of oil-filled transformer and analysis on correlation between mechanical characteristic such as tensile strength and chemical characteristics such as CO, CO2 gas and furfural when cellulose paper is aged by thermal. For experiment the accelerated aging cell has been manufactured, it has been aged during...
Because of environmental friendly and higher fire point, Natural ester fluids are widely used for transformer cooling materials. Natural ester has higher viscosity than that mineral oil. Top oil temperature and hottest temperature will be warmer when using natural ester fluid in transformers designed for conventional transformer oil. Although natural ester has less influence on deterioration of cellulose...
Insulating system of power transformers is mostly composed of two basic components: insulation oil and cellulose paper (oil-paper system). These components are of an organic nature and thatpsilas why they become very sensitive to operation degradation conditions (temperature, oxidation, moisture etc.). Aging of these components can endanger the failure free operation of the transformers. The main...