The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Doubly Fed Induction Generators (DFIG) has emerged as a suitable alternative for conversion of wind energy to grid quality energy under varying wind conditions. Often the control mechanism use large number of sensors and employ complex computations. Moreover, the reported control schemes for DFIG employing grid side converter (GSC) do not ensure a drawl of unity power factor (upf) sinusoidal current...
The paper describes the design of a Doubly Fed Induction Generator (DFIG) connected to the grid through back-to-back converters in the rotor circuit. A vector control oriented with the stator voltage is applied for the grid side converter that is responsible for maintaining the DC link voltage constant regardless of the power flow between the rotor and the grid. A field orientation control with the...
This paper presents an enhanced direct power control (DPC) algorithm for doubly fed induction generators (DFIG) capable of reducing the common mode voltage (CMV). Nowadays the DFIG is often used in high power wind energy conversion systems (WECS). A common problem of converter fed induction machines are the bearing damages due to the bearing currents. The source of this problem is the common mode...
The advancing technologies are boosting the wind turbine development rapidly and today the wind power generation has become a proven technology. However, still the research and development are motivated to go into further detail to simplify and optimize the control strategies. This paper addresses a simplified control strategy based on rotor current reference frame. The decoupled active and reactive...
The classical control techniques for regulating the active and reactive power delivery in doubly fed induction generators (DFIG), for wind power applications, are normally based on voltage oriented control (VOC) strategies. Among these algorithms, those that work in a synchronous reference frame, attached to the magnetic flux vector, became very popular. In spite of the good behaviour of such algorithms...
The classical control techniques for regulating the active and reactive power delivery in doubly fed induction generators (DFIG), for wind power applications, are normally based on voltage oriented control (VOC) strategies. Among these algorithms, those that work in a synchronous reference frame, attached to the magnetic flux vector, became very popular. In spite of the good behaviour of such algorithms...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.