The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper presents the extended travelling fire method (ETFM) framework, which considers both energy and mass conservation for the fire design of large compartments. To identify its capabilities and limitations, the framework is demonstrated in representing the travelling fire scenario in the Veselí Travelling Fire Test. The comparison between the framework and the test is achieved through performing...
For furnace testing of fire‐resistant floor and roof assemblies in the United States, the ASTM E 119 standard (and similarly the UL 263 standard) permits two classifications for boundary conditions: “restrained” and “unrestrained.” When incorporating tested assemblies into an actual structural system, the designer, oftentimes a fire protection or structural engineer, must judge whether a “restrained”...