Purpose
This study examined the clinical outcomes of a newly developed technique, arthroscopic suture bridge fixation with crossover ties of PCL tibial avulsion fracture using two tibial tunnels and a posterior trans-septal portal.
Methods
Records were reviewed of 18 patients (median age 33.5 years, range 13–55 years) with PCL tibial avulsion fractures treated with an arthroscopic suture bridge technique. Knee function before surgery and at last follow-up was evaluated by Lysholm and Tegner scores. A KT-2000 arthrometer was used to evaluate knee stability, and fracture union was assessed by plain radiographs.
Results
Mean postoperative Lysholm (P < 0.001) and Tegner (P = 0.011) scores showed significant improvements compared with preoperative scores. Arthrometry showed that the mean side-to-side difference improved significantly, from 7.8 ± 0.8 mm preoperatively to 3 ± 1.2 mm postoperatively (P = 0.012). Radiographic evaluation showed solid union at the fracture site in all 18 patients at last follow-up.
Conclusion
This new arthroscopic double-tunnel pull-out suture bridge fixation with multiple crossover ties and posterior trans-septal technique for PCL tibial avulsion fracture yielded good clinico-radiological outcomes, including satisfactory stability and fracture site healing. This technique can be a useful treatment option for PCL tibial avulsion fracture even with small comminuted fracture due to compression by the unique crossover configuration mesh of multiple fixation sutures.
Level of evidence
IV.