Background
Low-intensity ultrasound is a biophysical intervention on a fracture repair process. However, the effect of low-intensity ultrasound therapy on fracture healing is controversial. The aim of the present study was to evaluate the effect of low-intensity pulsed ultrasound (LIPUS) therapy on the fracture healing process, including mineral density and strength of callus using a rabbit model.
Methods
A total of 30 rabbits underwent unilateral, transverse, and mid-tibia open osteotomies that were stabilized with external fixators. Then, the animals were divided into two study groups composed of 15 rabbits each: the case group (US), which were exposed to low-intensity pulsed ultrasound with 30 mW/cm2 intensity and 1.5 MHz sine waves; and the control group (C), which underwent sham ultrasound treatment. Callus development and mineral density were evaluated using multidetector computed tomography at 2, 5, and 8 weeks, after which the animals were killed. Three-point bending tests of both healed and intact bones were assessed and compared.
Results
The results demonstrated that the callus mineral density in the US group was higher than in the C group (1202.20 ± 81.30 vs. 940.66 ± 151.58 HU; P = 0.001) at the end of the 8th week. The mean recorded three-point bending test score of healed bones in the US group was not significantly different from that of the C group (359.35 ± 173.39 vs. 311.02 ± 80.58 N; P = 0.114).
Conclusions
The present study showed that low-intensity pulsed ultrasound enhanced callus mineral density with an insignificant increase in the strength of the fractured bone.