The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
From October 2016 to September 2017, we performed tests of the ART-XC /SRG spare mirror system and detector unit at the 60-m-long IKI X-ray test facility. We describe some technical features of this test facility. We also present a brief description of the ART-XC mirror system and focal detectors. The nominal focal length of the ART-XC optics is 2700 mm. The field of view is determined by the combination...
We have performed calibration tests of a spare CdTe detector unit of the ART-XC/SRG telescope at the Space Research Institute’s 60-m-long X-ray test facility. During the tests, we illuminated the detector with a quasi-parallel X-ray beam generated by interchangeable X-ray tubes with different targets. To monitor the X-ray flux, we used two commercial detectors Amptek XR-100T-CdTe and XR-100SDD. We...