The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The necessary conditions for the diagnosability of control systems with a complex structure are given. It is shown that the topological conditions for detectability and localization of the fault signal do not depend on the class of operators of the dynamic model of the control system and are checked by using path search algorithms in directed graphs.
The necessary conditions for detecting and localizing the faults in control systems with a complicated structure are suggested. It is shown that the topological conditions do not depend on the class of operators of the dynamic model of the control system and are verified using path search algorithms in directed graphs. The fault localization algorithm is reduced to the construction and analysis of...