The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper proposes an error-voltage based open-switch fault diagnosis strategy for matrix converter (MC). First, finite control set-model predictive control (FCS-MPC) method is used to operate the MC. Meanwhile, based on the analysis of the operating state under fault condition, the fault model of MC is established. Second, the fault diagnosis strategy is implemented in three steps: to begin with,...