The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Dry biosignal electrodes for electro-encephalography (EEG) are an essential step for realization of ubiquitous EEG monitoring and brain computer interface technologies. We propose a novel electrode design with a specific shape for hair layer interfusion and reliable skin contact. An electrically conductive Titanium-Nitride (TiN) thin layer is deposited on a polyurethane substrate using a multiphase...
Continuous brain monitoring based on EEG recorded from surface electrodes is believed to have potentials in wearable medical devices. In such devices capacitive electrodes are attractive compared to conventional electrodes because there is no need for skin preparation and conductive gels, and because of diminished motion artifacts. However, there are technical challenges connected to the practical...
The cardiac action potential (AP) is produced by the orchestrated functions of ion channel dynamics. The coordinated functions can be simulated by computational cardiac cell models, which could not only overcome the practical and ethical limitations in physical experiments but also provide predictive insights on the underlying mechanisms. This investigation is aimed at modeling the variations of cardiac...
Brugada syndrome (BrS) causes sudden death in patients with structurally normal hearts. Manifestation of BrS in the ECG is dynamic and most patients do not show unequivocal signs of the syndrome during ECG screening. Electrograms (EGMs) of BrS patients show conduction delay and fractionation at the right ventricular outflow tract area (RVOT) and thus could be used for diagnosis, but their recording...
Though implantable cardioverter defibrillators (ICDs) are increasing in use in both adults and children, little progress has been devoted to optimizing device and electrode placement. To facilitate effective ICD placement, especially in pediatric cases, we have developed a predictive model that evaluates the efficacy of a delivered shock. We have also developed an experimental validation approach...
The inferior right atrial isthmus consisting of the terminal crest, the network of pectinate muscles, and the vestibule shows very complex anatomical structure. It is seen as potential substrate for atrial flutter. In this work we present results from an electro-anatomical characterization of this region based on Cardiac Near Field recordings taken from five preparations of rabbit atrium. Pectinate...
The presence of the electrical alternans induces, through the mechanism of the excitation-contraction coupling, an alternation in the heart muscle contractile activity. In this work, we demonstrate the cardiac alternans annihilation by applied mechanical perturbation. In particular, we address annihilation of alternans in realistic heart size tissue by considering ionic currents suggested by Luo-Rudy-1...
Computational modeling in electrocardiography often requires the examination of cardiac forward and inverse problems in order to non-invasively analyze physiological events that are otherwise inaccessible or unethical to explore. The study of these models can be performed in the open-source SCIRun problem solving environment developed at the Center for Integrative Biomedical Computing (CIBC). A new...
Recent empirical neuroscience evidence increasingly supports an active role for the endogenous electromagnetic (EM) field system of brain tissue. These results undermine the long-held view that the field system is a causally inert byproduct of action potential and synapse electrochemical activity. The dominant originating mechanism for the endogenous EM field remains undetermined. The new observations...
Bone cancer metastasis patients feel severe pain while performing rollover movement. We have been developing a robotic trunk orthosis to support the rollover movement in bed for bone cancer metastasis patients. In this support system, the myoelectric signal is used to recognize the start timing of the rollover movement. However, the characteristics of the myoelectric signal can change easily from...
Computational modeling of cardiac electrophysiology is a powerful tool for studying arrhythmia mechanisms. In particular, cardiac models are useful for gaining insights into experimental studies, and in the foreseeable future they will be used by clinicians to improve therapy for the patients suffering from complex arrhythmias. Such models are highly intricate, both in their geometric structure and...
Ultra-short, high-field electric pulses permeabilize plasma and intracellular membranes. We report here nanosecond pulse-induced permeabilization of mitochondrial membranes in living cells. Using four independent methods based on fluorescent dyes — JC-1, rhodamine 123, tetramethyl rhodamine ethyl ester, and cobalt-quenched calcein — we show that as few as five, 4 ns, 10 MV/m pulses delivered at 1...
Advances in neural electrode technology are enabling brain recordings with increasingly fine spatial and temporal resolution. We explore spatio-temporal (ST) patterns of local field potential spikes using a new high-density active electrode array with 500 μm resolution. We record subdural micro-electrocorticographic (μECoG) signals in vivo from a feline model of acute neocortical epileptiform spikes...
Event-related potentials (ERPs) of a visual processing task are compared with and without a simultaneous external working memory load. Ten adults participated the same measurement session on three separate days. Results for visual ERP P3 amplitude and reaction time (RT) are presented for both task conditions. Both the reaction time of the visual task and the respective P3 latency increased during...
Spatio-temporal dynamics of a mathematical model of myelinated axon in response to staircase-shape extracellular electrical stimulation, which was developed for selective nerve stimulation, is investigated by the computer simulation. It is shown that the response is classified into four types: subthreshold response, cathodic excitation, anodal block and anodal break excitation. Based on the simulation...
The ability to provide sensory feedback is desired to enhance the functionality of neuroprosthetics. Somatosensory feedback provides closed-loop control to the motor system, which is lacking in feedforward neuroprosthetics. In the case of existing somatosensory function, a template of the natural response can be used as a template of desired response elicited by electrical microstimulation. In the...
An epiretinal prosthesis aims to restore functional vision by stimulating electrically the retinal ganglion cells (RGCs) in patients affected by photoreceptor degenerative diseases, such as age-related macular degeneration (AMD) and retinitis pigmentosa (RP). During retinal degeneration, photoreceptor death is followed by pronounced remodeling and rewiring of inner retinal cells. Despite these changes,...
The ability to reconstruct gastric electrical activity (termed slow waves) non-invasively from potential field measurements made on the torso surface would be a useful tool to aid in the clinical diagnosis of a number of gastric disorders. This is mathematically akin to the inverse problem of electrocardiography. To investigate this problem, an anatomically realistic torso model and an electrical...
A cardiac sino-atrial tissue model based on a simplified 2D disc geometry and a generic ionic model is described and optimized to fit intact-tissue microelectrode experimental recordings. Concentric regions were defined representing the central and peripheral sino-atrial node and the atrium, each with a unique set of ionic model parameters. Intracellular action potentials were recorded from the respective...
Radiofrequency catheter ablation as a curative method for atrial fibrillation (AF) has become increasingly popular. Patients with paroxysmal AF have been treated by catheter ablation with great success, but so far this treatment has been less effective for patients with persistent AF. Usually there are multiple triggers or substrates during persistent AF and their exact locations are unclear. On the...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.