The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The aim of the paper is to identify the key physiological variables and ventilator settings involved in ventilation management, and required for an appropriate Clinical Decision Support System (CDSS). Based on the results of a questionnaire designed for the purpose of the research, 70 hours of physiological and ventilation data were recorded. Recorded data were classified by clinicians into three...
Coarctation of the aorta is an obstruction of the aorta and is usually associated with other concomitant cardiovascular abnormalities especially with bicuspid aortic valve stenosis. The objectives of this study are, (1) to investigate the effects of coarctation on the hemodynamics in the aorta to gain a better understanding of the cause of certain post-surgical coarctation problems, (2) to develop...
Atherosclerosis develops from oxidized low-density lipoprotein molecules (LDL). When oxidized LDL evolves in plaque formations within an artery wall, a series of reactions occur to repair the damage to the artery wall caused by oxidized LDL. Macrophages accumulate inside arterial intima, they started to collect oxidized LDL and form foam cells. Smooth muscle cells accumulate in the atherosclerotic...
A new index to assess left ventricular (LV) function in patients implanted with continuous flow left-ventricular assist devices (LVADs) is proposed. Derived from the pump flow signal, this index is defined as the coefficient (k) of the semiloga-rithmic relationship between “pseudo-ejection” fraction (pEF) and the volume discharged by the pump in diastole, (V d). pEF is defined as the ratio of the...
One factor which may be important for determining proper lesion creation in an atrial ablation procedure is catheter-endocardial contact. Little information is available that relates geometric contact, depth and angle, to ablation lesion formation. We present an electrothermal computer model of ablation that calculates lesion volume and temperature development over time. The Pennes bioheat equation...
Due to improved reliability and reduced risk of thromboembolic events, continuous flow left ventricular assist devices are being used more commonly as a long term treatment for end-stage heart failure. As more and more patients with these devices are leaving the hospital, a reliable control system is needed that can adjust pump support in response to changes in physiologic demand. An inlet pressure...
Continuous glucose monitoring systems are an integral component of diabetes management. Efforts to improve the accuracy and robustness of these systems are at the forefront of diabetes research. Towards this goal, a multi-sensor approach was evaluated in hospitalized patients. In this paper, we report on a multi-sensor fusion algorithm to combine glucose sensor measurements in a retrospective fashion...
Detection and quantification of rare circulating cells in biological tissues is an important problem and has many applications in biomedical research. Current methods normally involve extraction of blood samples and counting of cells ex vivo, or the use of microscopy-based fluorescence in vivo flow cytometry. The goal of this work is to develop an instrument for non-invasively enumerating very rare...
This paper presents the results of cardiovascular changes that occur during a novel rehabilitation strategy called activity based therapy (ABT). Blood volume pulse (BVP) signals were measured during functional electrical stimulation (FES)-induced cycling in adults with spinal cord injury (SCI) persons and results were compared to a passive cycling task and able-bodied controls performing normal cycling...
Abdominal aortic aneurysm (AAA) rupture is believed to occur when the mechanical stress acting on the wall exceeds the strength of the wall tissue. In endovascular aneurysm repair, a stent-graft in a catheter is released at the aneurysm site to form a new blood vessel and protect the weakened AAA wall from the pulsatile pressure and, hence, possible rupture. In this paper, we propose a framework to...
Analysis of exhaled trace gases is a novel methodology for gaining continuous and non-invasive information on the clinical state of an individual. This paper serves to explore some potential applications of breath gas analysis in anesthesia, describing a monitoring scheme for target site concentrations and cardiac output via physiological modeling and real-time breath profiles of the anesthetic agent...
This study examines the relationship between oxygen expired and functional near infrared spectroscopy (fNIRS) measured hemoglobin levels in the brain. Analysis of these two signals during normal versus deep breathing provides insight into the dynamics of cerebral physiology. Intersubject variation suggests the existence of two distinct groups with respect to oxygen extraction and hemoglobin levels.
This paper proposes an adaptive neuro-fuzzy model to study the pathophysiology of essential hypertension. Using diverse inputs such as risk factors, physical relations and medical interventions, and states that include both transient and resting states for key physiological variables (blood pressure, total peripheral resistance), it can roughly predict both real-time and long-term blood pressure change...
For patients suffering from cardiogenic shock cardiopulmonary resuscitation may not be sufficient to restore normal heart function. However, their chances of survival may be increased with the use of an extracorporeal support system. With this system the patient's organs are perfused while being transported to the nearest hospital for proper treatment. In the automation of an extracorporeal support...
The use of intravascular imaging modalities for the detection and assessment of atherosclerotic plaque is becoming increasingly useful. Current clinical invasive modalities assess the presence of plaque using anatomical information and include Intravascular Ultrasound (IVUS) and Optical Coherence Tomography (OCT). However, such modalities cannot take into account underlying functional biological information,...
We evaluated the in vivo performance of the Innovamedica pneumatic ventricular assist device (VAD), a new prototype of a simple, low-cost device for hospital circulatory support programs. We implanted the Innovamedica VAD in 6 sheep (weighing 55 to 91 kg). The inflow cannula was placed in the left ventricle, and the outflow cannula was anastomosed to the descending thoracic aorta. After heparinization...
To study the changes of cerebral oxygenation and hemodynamics in normal neonates at 2–5 min post-birth and understand the effects of pregnancy-induced hypertension (PIH) upon cerebral oxygenation and hemodynamics in newborn neonates. The near infrared spectroscopy (NIRS) was employed to measure the absolute quantity of brain tissue oxygen saturation (rSO2) in newborn neonates and the changes of concentrations...
We have developed a hydrodynamic levitation centrifugal blood pump with a semi-open impeller for a mechanically circulatory assist. The impeller levitated with original hydrodynamic bearings without any complicated control and sensors. However, narrow bearing gap has the potential for causing hemolysis. The purpose of the study is to investigate the geometric configuration of the hydrodynamic step...
A physiological control system was developed for a rotary left ventricular assist device (LVAD) in which the target pump flow rate (LVADQ) was set as a function of left atrial pressure (LAP), mimicking the Frank-Starling mechanism. The control strategy was implemented using linear PID control and was evaluated in a pulsatile mock circulation loop using a prototyped centrifugal pump by varying pulmonary...
This paper intends to define an optimal range for the pump speed of Rotary Left Ventricular Assist Devices (LVADs) that are used in bridge-to-recovery treatments. If the pump is operating within that optimal range, the aortic valve will be working properly (i.e. opening and closing) in each cardiac cycle. The proper operation of the aortic valve is a very important factor in helping the heart muscle...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.