The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper presents contributions on respiratory impedance and its phase constancy effects at high frequencies; i.e. 7.5-247.5 Hz. Measurements of 14 healthy volunteers are used to provide the input impedance values. It is shown, via the modulus-phase characteristics, that the impedance poses a typical frequency-independent behavior, known as phase constancy. We propose an electrical ladder network...
Radio frequency identification technology is used to power a novel platform of sensor devices. The employed energy harvesting system of the individual sensors enables a blanking of the radio frequency field for a defined period, while supplying the sensor electronics with a highly stable voltage. This guarantees interference free operation of the electronic circuitry during measurements. The implementation...
The aim of this study is to develop a method for measuring the respiratory waveform using non-contact electrodes during bathing. To determine the most appropriate electrode arrangement, we modeled a composite system consisting of a body submerged in bath water. We calculated the frequency dependence of the impedance amplitude using a three-dimensional finite difference method (3D-FDM). The simulation...
Gastric impedance spectroscopy has been proposed as a method of monitoring mucosal injury due to hypoperfusion and ischemia in the critically ill. During validation tests for this procedure, it was found that 60% of the measurements had errors by factors inherent to the clinical setting, indicating that some kind of automatic error detection should be incorporated to potentially avoid the loss of...
In many medical applications a well-directed positioning of a cannula in body tissue is mandatory. Especially the accurate placing of the cannula tip in the tissue is important for efficient drug delivery or for accessing blood vessels and nerves. This paper presents a new approach for a universal cannula navigation system based on tissue classification on the cannula tip by impedance spectroscopy...
Epilepsy affects nearly 3 million people in the United States alone. Given the fact that many people suffer from seizures that are intractable to pharmacological intervention, research groups are investigating the use of electrical stimulation to interact with and ameliorate symptoms of epileptic seizures. In mouse cortical slices made seizuregenic through chemical means, we applied precision controlled...
Mechanical impedance is a complex number and a system's property. Impedance of human arm is the control variable when the central nervous system coordinates a motion. This research proposes a new method for measuring the mechanical impedance as a complex number. Impedance is measured at the hand point while sinusoidal perturbation is applied. That helps extracting the real and imaginary part of the...