The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
A flowrate measurement method for air-water two-phase flow is developed using an Electrical Resistance Tomography (ERT) sensor and a Venturi meter. With the conductance values measured by the ERT sensor, the real-time flow pattern is identified and the voidage is also calculated. The Butterworth correlation is applied to calculate the mass quality from the voidage value, and then six Venturi measurement...
This paper reports recent advances in the optimisation of intrusive electrostatic sensors for the continuous velocity measurement of particles in pneumatic conveying pipelines. The effects of electrode dimensions and intrusion depth on sensor signals and correlation based velocity measurement have been investigated. Different cross sectional shapes of the electrodes have been compared. The optimum...
A measurement system is developed for the parameter detection and flow characterization of gas-liquid two-phase flow in micro-channel. Electrical capacitance measurement system and optical measurement system are designed for the micro-channels with different inner diameters of 4.0 mm, 3.1 mm and 1.8 mm respectively. In experiment, bubble flow, stratified flow, slug flow and annular flow are observed...
This paper presents the latest development in the velocity measurement of pulverized coal and biomass fuels in pneumatic pipelines using electrostatic sensors in combination with correlation signal processing techniques. A comparative study of electrostatic sensors with circular and rod electrodes was conducted on a 94mm bore horizontal pipeline feeding a 4 MW industrial scale furnace. Experimental...