The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper investigates virtual inertia control for dc microgrids using voltage droop control as the power-sharing strategy. An adaptive virtual inertia control (AVIC) strategy with the variable droop coefficient is proposed to increase the inertia of the dc microgrid. By swinging the droop curve during transient events, the dc voltage change rate is reduced. The variable droop coefficient is modified...
This paper presents a robustness-improving discrete-time current controller utilizing predictive current control (PCC) for permanent magnet linear synchronous motor (PMLSM). The stability and robustness of the PCC system is highly affected by the parameters mismatch between the controller and the plant, and the inherent digital control delay can limit the bandwidth. Toward this, an integrated method...
In order to meet the selectivity and the speed requirement of DC protections, this paper proposes a new DC protection scheme for DC substation systems. This scheme is developed based on the single-ended natural variation characteristics of DC current and its first and second derivatives under fault transients. It extracts the transient characteristic difference between the internal fault and external...
Three flux-regulation methods, namely stored capacitor discharge pulse (SCDP), constant current source pulse (CCSP) and quantitative flux-regulation pulse (QFRP), used for stator permanent magnet (PM) memory machine (MM), are comparatively studied in this paper. On the basis of analyzing the circuit topologies and flux-regulation principle of these flux-regulation methods, both simulation and experiment...
In order to improve the efficiency of high voltage power supply for electron beam welder, the characteristics of LCC series parallel resonant converter with capacitive filtering are studied in this paper, and the circuit model of LCC resonance in discontinuous current mode(DCM) is established. The working mode of the converter is analyzed by mathematical time domain analysis method, and the mathematical...
In order to reduce the torque ripple and improve the torque-speed characteristic of switched reluctance motor, a novel predictive current control method is proposed in this paper. Compared with conventional current hysteresis control, the current tracing ability is improved by using proposed method without increasing switch frequency or changing hysteresis band. Both of torque ripples and copper loss...
This paper presents a new method for energy management in distribution networks in the presence of energy storage, solar photovoltaic (PV) systems and diesel generators. Achieving optimal charge and discharge pattern for batteries and optimal diesel generator output with minimal operation cost are the main goal of this paper. The innovation of this paper is to consider the network effect on the underlying...
As the use of electric energy increases rapidly due to the development of the worldwide industry, The ESS is attracting much attention in terms of efficient energy use. The ESS consists of various components such as battery, BMS, PCS and PMS. And PCS is the largest weight and volume among these components. The reasons are that the reactor for the high-frequency filter and the isolation transformer...
In order to reduce noise and vibration in switched reluctance motors (SRM), many kinds of commutation methods have been proposed. One of them is well-known as 2-stage commutation method. However, it has a defect which is revealed particularly when SRM is operated at high speed and high load condition. In this study, through the magnetic-structural coupled analysis using FEM and the mathematical analysis...
A novel extended state observer (ESO)-based vector control (VC) strategy is developed for permanent magnet synchronous motor (PMSM) drive systems with only one phase current sensor. Generally, to achieve high precision control, two phase current sensors are indispensable for successful operation of the feedback control. In response to a phase current sensor fault, by use of technique of ESO, a new...
With the rapid increase of the substation grade, the number of ultra-high voltage (UHV) transformer is increasing and the noise caused by the vibration of UHV transformer is becoming more and more serious. The vibration of UHV transformer is mainly generated from the magnetostrictive effect of the iron core and the action of the electromagnetic force of the winding. In this paper, the sound intensity...
Most of magnetic encoder ICs are on-axis, and they are generally suitable for inner rotor PMSM, sometimes used in external rotor PMSM. However, in some special occasions, these ICs are not used for the difficulty of mounting, for example, there is an external rotor PMSM with a hollow shaft, which is convenient for passing the control wire. It is difficult to mount these encoder ICs, because there...
In this paper, a new control method of single phase phase-locked loop (PLL) function which can be useful in the electric railway PWM converter system is presented. New PLL system does not use conventional all pass filter (APF) algorithm. Instead, modified moving average filter (mMAF) which has a simple calculation is newly proposed. The feasibility of proposed mMAF method was investigated through...
ISOV (Input Series Output Parallel) modular DAB (Dual Active Bridge) converter based topologies have been mostly considered for solid-state transformer (SST) based power substation design, involving multilevel converters at the medium-voltage side. As DAB converter is one of the core components of this topology, an important question to address is thus the freewheeling currents of DAB which increases...
This paper presents an electro-thermal based junction temperature (Tj) estimation method of insulated gate bipolar transistor (IGBT) power module. Firstly, the internal structure of IGBT and its transient characteristics are researched, through which the factors affecting the power loss as well as its basic influence rule are analyze and the multivariable loss calculation model is obtained. And then...
This paper presents both analysis and experimental verification of applying Selective Harmonic Elimination (SHE) technique for cascaded half-bridge multilevel inverters. The inverter units are fed from PV modules throughout step-down dc-to-dc converters to regulate the inverter input voltage. The inverter has to be asymmetric which allows more possibility to connect PV modules to get maximum possible...
According to the requirement of the power factor and the dynamic performance of the asynchronous machine tool field, an asynchronous motor inverter with active power factor correction is proposed. The proposed inverter is a 3kW asynchronous motor drive control platform. At first, the proposed single phase converter with APFC is realized by using the MATLAB/SIMULINK. Then, the boost APFC is designed...
This paper proposes a model predictive torque-vector control (MPTVC) scheme for four-switch three-phase inverter (FSTPI)-fed permanent magnet synchronous motor (PMSM). A cost function consist of a new constructed reference torque-vector is designed. Thus, the control of the FSTPI-fed motor drive with the capacitor voltages dc offset suppression can be ensured by only tracking the reference torque-vector...
Clustering is a well-recognized data mining technique which enables the determination of underlying patterns in datasets. In electric power systems, it has been traditionally utilized for different purposes like defining customer load profiles, tariff designs and improving load forecasting. Some surveys summarized different clustering techniques which were traditionally used for customer segmentation...
In dq-frame current control scheme for single-phase grid-connected inverters, an orthogonal signal generation (OSG) block is required to generate a virtual orthogonal signal. The OSG block makes the control system complicated and introduces extra disturbance, which deteriorates the dynamic performance. This paper presents a simplified dq-frame current controller for single-phase grid-connected inverters...