The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
A fully-automatic ultrasound image processing system that can determine the needle entry site for epidural anesthesia (EA) in real time is presented in this paper. Neither the knowledge of anesthetists nor additional hardware is required to operate the system, which firstly directs the anesthetists to reach the desired insertion region in the longitudinal view, i.e., lumbar level L3-L4, and then locates...
Limited field of view (FOV) is a major problem for 3D real-time echocardiography (3DRTE), which results in an incomplete representation of cardiac anatomy. Various image registration techniques have been proposed to improve the field of view in 3DRTE by fusing multiple image volumes. However, these techniques require significant overlap between the individual volumes and rely on high image resolution...
Cardiac output is an important variable when monitoring hemodynamic status. In particular, changes in cardiac output represent the goal of several circulatory management therapies. Unfortunately, cardiac output is very difficult to estimate, either in experimental or clinical settings. The goal of this work is to compare four techniques to measure cardiac output: pressure-volume catheter, aortic flow...
In this paper, we study neuronal network analysis based on microelectrode measurements. We search for potential relations between time correlated changes in spectral distributions and synchrony for neuronal network activity. Spectral distribution is quantified by spectral entropy as a measure of uniformity/complexity and this measure is calculated as a function of time for the recorded neuronal signals,...
Flowing emboli in the circulatory system cause fatal diseases such as stroke or pulmonary embolism. Conventional transcranial Doppler ultrasound for detection of emboli requires precise positioning by experienced examiner. In the present study, an easier emboli detection device by visualizing perspective view of blood vessel is proposed. The perspective image was obtained with continuous wave (CW)...
Doppler ultrasound is a non-invasive diagnostic tool for the quantitative measurement of blood flow. However, given that it provides velocity data that is dependent on the location and angle of measurement, repeat measurements to detect problems over time may require an expert to return to the same location. We therefore developed an image-guidance system based on ultrasound B-mode images that enables...
Continuous monitoring of blood oxygen saturation (SpO2) level and heart rate is critical in surgery, ICUs and patients suffering from Chronic Obstructive Pulmonary Diseases. Pulse oximeters which compute SpO2 using transmittance photoplethysmography (PPG), is widely accepted for continuous monitoring. Presence of motion artifacts in PPG signals is a major obstacle in the extraction of reliable cardiovascular...
Dual-mode multielectrode recordings have become routine in rodent neuroscience research. However, robust and reliable application of acute, multielectrode recording methods in brain especially for in vivo research remains a challenge. In patients with Parkinson's disease (PD), the efficacy of L-dopa therapy depends on its ability to restore Dopamine (DA) neurotransmission in the striatum. In this...
We here demonstrate multi-chip heterogeneous integration of microfabricated extracellular recording electrodes with neural amplifiers, highlighting a path to scaling electrode channel counts without the need for more complex monolithic integration. We characterize the noise and impedance performance of the heterogeneously integrated neural recording electrodes, and analyze the design parameters that...
We report on the concept, development, and geometrical, optical as well as electrical characterization of the first three-dimensional (3D) optrode. This new device allows to optically interact with neuronal cells and simultaneously record their response with a high spatial resolution. Our design is based on a single-shank optical stimulation component and a multi-shank recording probe stacked together...
This work presents a novel method for protein or cancer antigen detection in clinical samples by an immunogold-silver assay microfluidic biochip coupled with a polythiophene-based organic photodetector. The method has showed a detection limit below 1ng/mL and the low cost and high sensitivity of both organic photodetector and immunogold-silver assay make this method amenable for realization in a portable...
Radiofrequency ablation (RFA) is a minimally invasive procedure used to treat tumors by means of hyperthermia, mostly through percutaneous approach. The tissue temperature plays a pivotal role in the achievement of the target volume heating, while sparing the surrounding healthy tissue from thermal damage. Several techniques for thermometry during RFA are investigated, most of them based on the use...
We present an inexpensive imaging system for measuring the diffuse surface radiance profile produced by a light source within a turbid medium. The diffusion model of light propagation in multiple scattering media is used to estimate the optical properties of a sample and subsequently approximate the depth of an optical source. The system is shown to accurately estimate the relative changes in source...
The development of novel neurotechnologies for treating refractory neuropsychiatry disorders depends on understanding and manipulating the dynamics of neural circuits across large-scale brain networks. The mesolimbic pathway plays an essential role in reward processing and mood regulation and disorders of this pathway underlie many neuropsychiatric disorders. Here, we present the design of a customized...
Stroke is a leading cause of functional impairments. The typical screening mechanism is to measure localized Peak Systolic Velocity (PSV) and diagnose impending risk associated with stoke by characterizing the PSV values. However, an accurate measurement of PSV using Doppler ultrasound is affected due to the tortuous nature of carotid artery in elder population group as the angle at which acoustic...
This paper reports a novel neurotechnology (Neuronix) and its validation through experiments. It is a miniature system-on-chip (SoC) that allows recording with simultaneous electrical microstimulation. This function has not been demonstrated before and enables precise, closed-loop neuromodulation. Neuronix represents recent advancement in brain technology and applies to both animal research and clinical...
A novel sensor placement method for better removal of motion artifacts (MA) from photoplethysmography (PPG) signal using Fast Independent Component Analysis (ICA) is proposed in this paper. The method enhances the determination of pulse transit time (PTT) of PPG signals. The design makes use of double reflectance mode based PPG probes, which are placed complementary to each other and on the two sides...
This study explored the psychophysical effects of intracortical microstimulation (ICMS) coupled to auditory stimulation during a behavioral detection task in rats. ICMS directed to the sensory areas of the cortex can be instrumental in facilitating operant conditioning behavior. Moreover, multisensory stimulation promotes learning by enabling the subject to access multiple information channels. However,...
To understand the complex correlations between neural networks across different regions in the brain and their functions at high spatiotemporal resolution, a tool is needed for obtaining long-term single unit activity (SUA) across the entire brain area. The concept and preliminary design of a distributed free-floating wireless implantable neural recording (FF-WINeR) system are presented, which can...
Multimodal brain monitoring is an important approach to gain insight into brain function, modulation, and pathology. We have developed a unique micromachined neural probe capable of real-time continuous monitoring of multiple physiological, biochemical and electrophysiological variables. However, to date, it has only been used in anesthetized animals due to a lack of an appropriate interface for awake...