The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Although bipolar nerve cuff electrodes (NCEs) are used in clinical neurostimulation therapies (e.g., epilepsy, obstructive sleep apnea), the use of this electrode as part of a closed-up controlled system is very limited. The literature points to high noise content (i.e., poor signal-to-noise ratio, SNR) as the primary reason for not using bipolar NCEs to record neural activity. In fact, over the past...
The global inhomogeneity (GI) index is a electrical impedance tomography (EIT) parameter that quantifies the tidal volume distribution within the lung. In this work the global inhomogeneity index was computed for twenty subjects in order to evaluate his potential use in the detection and follow up of chronic obstructive pulmonary disease (COPD) patients. EIT data of 17 subjects were acquired: 14 patients...
Wireless links with implantable devices can help in real-time monitoring of symptoms, irregularities, implanted device efficacy and their reconfiguration. We present the design of a low-power wideband voltage controlled oscillator (VCO) to facilitate implantable wireless telemetry. A coupled SAW-LC resonator design combines high Q and spectral purity of a SAW element and tunability of an LC-tank....
In this study, we developed and tested a novel adaptive controller for powered transfemoral prostheses. Adaptive dynamic programming (ADP) was implemented within the prosthesis control to complement the existing finite state impedance control (FS-IC) in a prototypic active-transfemoral prosthesis (ATP). The ADP controller interacts with the human user-prosthesis system, observes the prosthesis user's...
The accumulation of fluid in the legs due to sedentariness can be a health risk in extreme cases. Negative health impacts associated with leg fluid accumulation include leg edema and risk of blood clots. Furthermore, fluid accumulating in the legs is accompanied by fluid shift into the upper body which is also associated with health risks such as: increased blood pressure when lying down, respiratory...
This paper presents a high-efficiency RF powering system, suitable for individual health monitoring applications. The system is composed of an antenna, an impedance matching network, and a two-stage full-wave RF-DC rectifier. A novel tuning mechanism is proposed to automatically adjust the impedance of the matching network. This mechanism can effectively improve the power efficiency of the system...
In this paper, we propose a novel computer vision technique to measure respiration rate by counting the periodic thoracoabdominal motion in real-time using an inexpensive consumer grade camera. We compute the component of optical flow parallel to the image gradient at each pixel, which is a computationally inexpensive operation. Then, we find a principal flow field by gathering information over many...
Microfabricated interdigitated electrode chips have been designed for use in a unique gold-nanoparticle based biosensor system. The use of these electrodes will allow for simple, accurate, inexpensive, and portable biosensing, with potential applications in diagnostics, medical research, and environmental testing. To determine the optimal design for these electrodes, finite element analysis simulations...
This paper proposes a novel method to fabricate high resolution flexible electrodes. Among the steps, the carbon nanotube (CNT) electrodes synthesized facing down shows impedance improvement of about 90 times comparing with the normal facing up synthesized samples. Meanwhile, section impedance of electrodes is also defined in this paper to compare the area efficiency of impedance between electrodes...
There has been a push for a greater number of channels in implantable neuroprosthetic devices; but, that number has largely been limited by current hermetic packaging technology. Microfabricated packaging is becoming reality, but a standard testing system is needed to prepare these devices for clinical trials. Impedance measurements of electrodes built into the packaging layers may give an early warning...
Powered knee prostheses provide substantial advantages for amputees compared to traditional passive devices during basic walking tasks (i.e. level-ground, stairs, ramps), but the impedance control parameters are fixed. For environments that differ from the well-controlled setting of the clinic, amputees must compensate their gait patterns because fixed control parameters ideal for walking on level...
Mathematical modeling for composition distal arterial pulse wave in the blood vessels of the upper limbs was considered. Formation of distal arterial pulse wave is represented as a composition of forward and reflected pulse waves propagating along the arterial vessels. The formal analogy between pulse waves propagation along the human arterial system and the propagation of electrical oscillations...
This paper presents the operation of a dualmode wideband CMOS analog front-end (AFE) for electrical impedance spectroscopy. The chip combines two current-readout (CR) channels and four voltage-readout (VR) channels suitable for both bipolar and tetrapolar EIS analysis. The chip addresses the need for flexible readout units for real-time simultaneous single-cell and large scale tissue/organ analysis...
Dual-mode multielectrode recordings have become routine in rodent neuroscience research. However, robust and reliable application of acute, multielectrode recording methods in brain especially for in vivo research remains a challenge. In patients with Parkinson's disease (PD), the efficacy of L-dopa therapy depends on its ability to restore Dopamine (DA) neurotransmission in the striatum. In this...
In-stent restenosis (ISR) is a frequent complication after stent implantation. Recently, a passive sensor system for integration into a stent has been presented, which is designed to detect an ISR early by measuring the local pulse wave velocity (PWY). This system is based on two pressure sensitive transponders, the resonance frequency of which hits the frequency of a magnetic field generated by an...
Electrochemical impedance spectroscopy (EIS) is a widely used technique in biomedical and chemical analysis. A prototype of comparative frequency response analysis (FRA) system for measuring EIS is proposed in this work. Compared to traditional FRA-based systems, neither quadrature sinusoidal signals nor two identical sensing paths are needed. The experimental results based on molecularly imprinted...
Objective. The work presented here describes a new tool for peripheral nerve interfacing, called the microneedle cuff (μN-cuff) electrode. Approach. μN arrays are designed and integrated into cuff electrodes for penetrating superficial tissues while remaining non-invasive to delicate axonal tracts. Main results. In acute testing, the presence of 75 μm height μNs decreased the electrode-tissue interface...
Electrodes are used to transform ionic currents to electrical currents in biological systems. Modeling the electrode-electrolyte interface could help to optimize the performance of the electrode interface to achieve higher signal to noise ratios. There are previous reports of accurate models for single-element biomedical electrodes. In this paper we develop a model for the electrode-electrolyte interface...
In this paper, a bio-impedance analysis (BIA) based wrist-worn heartbeat monitoring system is proposed. The system is able to estimate heart rate from a subject's wrist with only four electrodes. The design is achieved with a standard BIA device and off-the-shelf components for signal conditioning. The measured heartbeat-related impedance signal is compared with a reference heart rate signal obtained...
Electrode and cap concepts for continuous and ubiquitous monitoring of brain activity will open up new fields of application and contribute to increased use of electroencephalography (EEG) in clinical routine, neurosciences, brain-computer-interfacing and out-of-the-lab monitoring. However, mobile and unobtrusive applications are currently hindered by the lack of applicable convenient and reliable...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.