The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper describes a general computer model for a high power SCR that gives an accurate simulation of all important static and dynamic performance characteristics including such two-dimensional effects a spreading, gate isolation, and latch-in. Computer simulated vs. measured static characteristics of a representative device are listed for comparison. A comparison of a computer simulated vs. measured...
A method for measurement of the instantanuous inductance L(t) of an iron core inductor is presented as function of the inductor current i, the rate of change di/dt of this current and the past history of the iron core at that moment. The inductance of a filter inductor is shown as a function of unidirectional continuous and discontinuous currents. The concept of an equivalent time invarying inductance...