The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Fuse-saving practices have coordination limitations at higher current levels — it is common for the upline device to trip and the fuse to operate at the same time. The result is frequent momentary outages for many customers and blown fuses, even for temporary faults. These challenges have led some utilities to abandon the practice of fuse-saving and instead migrate to a fuse-blowing philosophy. The...
Busbar protection is described for a bus with current inputs for up to 32 bays. For busbar protection with IEDs and MUs using IEC61850–9–2 process bus, communication traffic jams are the main concern, due to transferring 80 samples/cycle data from all bay MUs to IED via 100BASE-FX. This paper describes peer-to-peer connection between MUs and IED in order to segrigate the SV messages of 32 bays on...
The concentration of electric power at system buses adds to both the need for high-speed tripping in case of faults and the need to avoid false tripping in case of external faults. This combined need for both superior dependability and security has led to many enhancements and system modifications in bus protection. Bus configurations with multiple zones are particularly difficult to provide with...
A common practice for improving electric service reliability is to provide an alternate source of supply. On the distribution system, two feeders — each with one or more mid-line overcurrent protective devices — can be tied together through a normally-open tie point to restore service to unfaulted sections of line. Conventional looped distribution systems rely on overcurrent coordination to ensure...
Wide-area Situational Awareness (WASA) is of key importance in power system operators' decision-making. Lack of WASA can set in motion cascading failures, or contribute to the development of a blackout. Inadequate WASA was actually identified as one of the major causes of several blackouts in the last decade. A variety of factors in a power system control centre can affect the formation of WASA, especially...
Adaptive power system protection can be used to improve the performance of existing protection schemes under certain network conditions. However, their deployment in the field is impeded by their perceived inferior reliability compared to existing protection arrangements. Moreover, their validation can be problematic due to the perceived high likelihood of the occurrence of failure modes or incorrect...
This paper reviews the characteristics of inrush current and analyses its causes. The development of digital substation and the concept of integrated protection are also outlined. The paper studies different models to simulate several kinds of inrush and internal short-circuit fault. Through these models, the new composite algorithm is analysed in order to verify the reliability and sensitivity of...
Transmission level protection functions are increasingly being looked at for Distribution systems. This can be attributed mainly to the enhancements being planned for by the Operating Companies, to increase the system efficiency, and also to ensure reliable power supply to the end Consumers. Slowly, the catch word "Smart Grid" is being consciously and progressively transformed to practical...