The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Locating high-resistance grounding faults poses a tough and challenging problem for the safety of DC railway systems. High-resistance grounding fault current isn't sufficient to trigger switches, which may expand the accident or turn into potential hazards. In order to overcome the limits of the existing methods (such as signal injecting method, resistance method and so), developing a novel fault...
Most of current arc suppression coil compensation system works based on the magnitude of post-fault distributed capacitance. This system can not offer compensation before fault, so in power system with large distributed capacitance current, short circuit shock is inevitable. This paper proposes an automatic arc suppression coil compensation technology based on fixed-frequency signal injection, it...
Distribution system operator (DSO) sometimes needs to operate the large network which means operating of the network with big capacitive current (in Czech Republic more than 800A). This operation puts the emphasis not only on the setting of the earth fault relays but on the safety of the point of fault too. The paper describes the theoretical analysis, simulation and tests in real compensated distribution...
This paper presents a novel approach designed for centralize substation level protection to determine the faulty feeder in a distribution network In opposite to phase-to-earth faults in the transmission networks (HV), which neutral points are solidly earthed, fault-loops in a fault-to-earth case in MV distribution networks have big impedance. Additionally during the earth-fault the transient component...
Injection-based 100% stator earth-fault protection has been used for many years. However traditionally signals with frequency between 10Hz and 25Hz have been injected into the stator winding. To inject such a signal, either a dedicated grounding transformer with secondary grounding resistor or injection on primary side of the grounding circuit, is normally used. This paper will present a novel approach...