The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
In cardiovascular diagnostics, phase-contrast MRI is a valuable technique for measuring blood flow velocities and computing blood pressure values. Unfortunately, both velocity and pressure data typically suffer from the strong image noise of velocity-encoded MRI. In the past, separate approaches of regularization with physical a-priori knowledge and data representation with continuous functions have...
Flow-mediated dilatation (FMD) is the most accepted technique for the evaluation of endothelial function. However, it has been show a great inter-subject variability limiting its clinical use. Carotid-radial pulse wave velocity (PWVcr) was proposed as an alternative tool for the evaluation of endothelial function. At the present, there is no doubt that PWVcr reduces its values in response to reactive...
Hemorrhagic stroke accounts for more than 15% of all stroke hospitalization with much higher mortality than ischemic stroke. In this study, we investigated the spatiotemporal changes of the cerebral blood flow (CBF) following intracerebral hemorrhagic (ICH) stroke by laser speckle imaging. Adult male C57BL/6 mice were divided into ICH group (n=7) and saline group (n=4). CBF images were recorded before...
Advances in medical imaging and screening tests have made possible the detection and diagnosis of many diseases in their early stages. Those advances have enabled more effective planning, execution, and monitoring of a treatment plan. However, early detection has also resulted in an increase of the number of longitudinal radiographs requested for most patients, thus increasing the risk for potential...
We have developed a hydrodynamic levitation centrifugal blood pump with a semi-open impeller for a mechanically circulatory assist. The impeller levitated with original hydrodynamic bearings without any complicated control and sensors. However, narrow bearing gap has the potential for causing hemolysis. The purpose of the study is to investigate the geometric configuration of the hydrodynamic step...
A physiological control system was developed for a rotary left ventricular assist device (LVAD) in which the target pump flow rate (LVADQ) was set as a function of left atrial pressure (LAP), mimicking the Frank-Starling mechanism. The control strategy was implemented using linear PID control and was evaluated in a pulsatile mock circulation loop using a prototyped centrifugal pump by varying pulmonary...
Blood flow should be measured to monitor conditions of patients with implantable artificial hearts continuously and noninvasively. We have developed a noninvasive miniaturized mass-flow meter using a curved cannula for an axial flow blood pump. The mass-flow meter utilized centrifugal force generated by the mass-flow rate in the curved cannula. Two strain gauges served as sensors. Based on the numerical...
This paper intends to define an optimal range for the pump speed of Rotary Left Ventricular Assist Devices (LVADs) that are used in bridge-to-recovery treatments. If the pump is operating within that optimal range, the aortic valve will be working properly (i.e. opening and closing) in each cardiac cycle. The proper operation of the aortic valve is a very important factor in helping the heart muscle...
Analysis of exhaled trace gases is a novel methodology for gaining continuous and non-invasive information on the clinical state of an individual. This paper serves to explore some potential applications of breath gas analysis in anesthesia, describing a monitoring scheme for target site concentrations and cardiac output via physiological modeling and real-time breath profiles of the anesthetic agent...
A new suction detection algorithm for rotary Left Ventricular Assist Devices (LVAD) is presented. The algorithm is based on a Lagrangian Support Vector Machine (LSVM) model. Six suction indices are derived from the LVAD pump flow signal and form the inputs to the LSVM classifier. The LSVM classifier is trained and tested to classify pump flow patterns into three states: No Suction, Approaching Suction,...
Coarctation of the aorta is an obstruction of the aorta and is usually associated with other concomitant cardiovascular abnormalities especially with bicuspid aortic valve stenosis. The objectives of this study are, (1) to investigate the effects of coarctation on the hemodynamics in the aorta to gain a better understanding of the cause of certain post-surgical coarctation problems, (2) to develop...
New scenarios in diabetes treatment have been opened in the last ten years by continuous glucose monitoring (CGM) sensors. In particular, Non-Invasive CGM sensors are particularly appealing, even though they are still at an early stage of development. Solianis Monitoring AG (Zürich, Switzerland) has proposed an approach based on a multisensor concept, embedding primarily dielectric spectroscopy and...
Background: Although Guyton's concept of venous return (VR) revolutionized circulatory physiology, the pulmonary circulation is invisible in its original framework. Since the pulmonary circulation is critical in left heart failure, we characterized the VR as a surface described by right (PRA) and left atrial (PLA) pressures and demonstrated that the VR surface was capable of representing mechanics...
Bone tissue engineering offers perhaps the most attractive treatment option for bone repair/regeneration as it eliminates complications of other bone grafting options (i.e., availability and immunogenicity issues of autografts and allografts, respectively). However, scaffold-based bone tissue engineering is largely limited by inadequate vascaularization, and as a result, bone formation is often restricted...
The effect on acid-base balance efficacy of intermittent warm and cold blood cardioplegia (IWBC, ICBC) was assessed in 44 patients who underwent cardiac surgery with prolonged aortic cross clamping. With this purpose a customized multi sensor probe was inserted in the coronary sinus, and pH, PO2, PCO2 and temperature were continuously measured at 1 Hz sampling rate. The mean cross-clamping time was...
We report a field-portable lensless on-chip microscope with a lateral resolution of <1μm and a large field-of-view of ∼24mm2. This microscope is based on digital in-line holography and a pixel super-resolution algorithm to process multiple lensfree holograms and obtain a single high-resolution hologram. In its compact and cost-effective design, we utilize 23 light emitting diodes butt-coupled to...
Thermal ablation of a tumour in the liver with Radio Frequency energy can be accomplished by using a probe inserted into the tissue under the guidance of medical imaging. The extent of ablation can be significantly affected by heat loss due to the high blood perfusion in the liver, especially when the tumour is located close to large vessels. A mathematical model is thus presented here to investigate...
New approaches to fairly old noninvasive cardiology tools, based on studying low frequency vibrations created by the heart on the body, were reviewed. These signals were divided and studied in two categories and compared in their capability for estimation of hemodynamic parameters. In particular one representative signal of each category, seismocardiogram and ultra-low frequency ballistocardiogram,...
Most pulse oximeters determine blood oxygen saturation (SpO2) after calculating a coefficient, R, that represents the normalized ratiometric contributions of the pulsatile red and near-infrared photoplethysmograms (PPGs) acquired by the sensor. This paper presents a new approach that uses principle component analysis (PCA) to separate the signal and noise components of unfiltered PPGs and provide...
In guideline E14, the American Food and Drug Administration (FDA) requests for clinical studies to investigate the prolongation of the heart rate corrected QT-interval (QTc) of the ECG. As drug induced QT-prolongation can be caused by changes in the repolarisation of the ventricles, it is so far a thorough ECG biomarker of risk for ventricular tachyarrhyth-mias and Torsade de Pointes (TdP). Ventricular...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.