The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Static var compensator (SVC) and thyristor controlled series compensator (TCSC) are used to improve Transient Voltage Stability of the asynchronous wind farm in this paper. The related structure model of the wind farm power system is built in Matlab / Simulink. The contributions of SVC and TCSC to Transient Voltage Stability of the asynchronous wind farm and power grid are verified by the simulation...
With the introduction of new guidelines regarding the connection of large wind farms to the grid, wind farms and equipment providers are facing with new opportunities and challenges. One of which is low voltage ride-through (LVRT). Despite of the new installations, there are a considerable number of wind turbines to be reformed to meet the requirements. In this paper, a brief explanation of the principle...
This paper presents the possible improvements of voltage quality in connection of a wind farm to transmission network using VSC-HVDC (Voltage source converter high voltage direct current) link. For a 80 MW wind farm consisting of 40 individual 2 MW doubly fed induction generators, the main influence of voltage fluctuation caused by the wind farm integration is analyzed. The use of a reactive controller...
Wind generation rapid development has brought challenge to the grid. Reactive voltage is the most outstanding and one of the most concerned problems. This paper introduces the concept of wind farms reactive power compensation and wind power grid code with respect to reactive power regulation all over the world, gives the simplified approach to estimate reactive power compensation capacity, and validates...
In accordance with the randomness and intermittent characteristics of wind power, the static synchronous compensator (STATCOM) is more competent and competitive for reactive power compensation in large scale wind farm. An average state model for the VSC-STATCOM is derived, according to the wind farm reactive power compensation characteristics, a novel decoupling control strategy of active power and...
An accurate model of large scale wind farm is demanded for researches about the impacts on the power grid. The total number of wind energy generators is so large that the detailed model of wind farm is computationally prohibitive. Dynamic equivalence can significantly reduce system order with the major characteristics retained. So the aggregation of large scale wind farm is inevitable. An overview...
Wind generation has been the fastest growing power source over the past decade and this growth is forecasted to continue. Grid code requirements on wind power plant are becoming more stringent as the wind power penetration level increases. In order to identify the risk of incompliant with grid code requirements at the planning stage of a wind power plant project, a standard grid code study process...
The fast development of wind power generation brings new necessary requirement for wind turbine to provide Low Voltage Ride-Through (LVRT) capability. The paper introduces the models of Doubly Fed Induction Generator (DFIG), converter and rotor active crowbar, and analyses characteristics of DFIG system with rotor active crowbar during grid voltage dip. A novel turn-on and turn-off control method...
This paper presents the relevant aspects related to large scale integration of wind power into the power system. Grid integration of WPPs is a technical and economic ability of WPPs to connect and operate within the electric power supply network in a manner which is compatible with the day-to-day operation and short-term security of the electric supply as a whole. WPPs when connected to a weak grid...
The induction generators are basic to wind energy conversion. They produce the active power and consume reactive power, with the voltage characteristics fragile compared with that of the synchronous generators. In stressed system conditions, they may intensify var imbalance, causing undesirable operation of the zone 3 impedance relays (mho relays). In this paper, the static voltage characteristics...