The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The combination of extensive cable networks and wind turbine converters has been identified as a potential cause of resonances. A modelling approach for a doubly fed induction generator and a full power converter fed generator for harmonic penetration studies is developed and discussed. An example offshore wind farm is then studied in the simulation package IPSA using the detailed wind turbine generator...
Wind energy is the fastest growing source of renewable energy in the power industry and it will continue to grow worldwide as many countries are developing plans for its future development. For power system operators, this increasing contribution of wind energy to the grid poses new challenges that need to be addressed in order to ensure the reliability and security of the electric power grid. One...
Wind generation is evolving from single wind turbines to wind power plants with an installed capacity of tens of megawatts. Therefore, wind turbines are also coupled to the transmission grid instead of the distribution grid. Problems arise during grid faults as the behaviour of wind turbines equipped with doubly-fed induction generators differs fundamentally from traditional synchronous generators...
The paper deals with permanent magnet synchronous generators based wind farms connected to a single power HVDC-VSC converter. A control scheme is proposed and validated by means of simulations. The proposed control scheme needs only current and voltage measurements in the wind farm transformer and seeks the maximum power generation using a variable frequency offshore grid, provided by the HVDC-VSC...
Shorted stator induction generator (IG) is presented for low wind speed power application. An analytical model is derived for predicting electrical performance of the generator while operating in regions 1 and 2 of turbine power versus wind speed curve. This paper determines an explicit optimal stator electrical speed of operation since the stator is disconnected from synchronism with the grid. A...
The paper proposes a Fuzzy logic approach for controlling three-level NPC converters in stand alone wind energy systems. A key function of this controller is to maintain constant voltage and frequency for customers while maintaining smooth voltage waveform with less filtering requirements. The principle of the proposed Fuzzy controller is based on a modified PI approach in which the error and its...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.