An indirect impedance measurement approach that does not require direct cable attachment or large space using a two-port network is presented. Using a straight wire monopole as an interrogating antenna and measured impedances of three calibration standards, the input impedance of a small spherical helix dipole over a ground plane is retrieved. It is found that accurate result is obtained around the dipole resonance frequency. The accuracy and sources of error are discussed.