The fundamentals of a radiation sensor based on flame spectral analysis in an industrial combustion application are presented. We calculates the radiation emitted by the flame, by integrating the estimation of the continuous component of the flame spectra. We compare the performance of the calculated radiation, respect to other optical variables proposed as combustion indicators. The proposed radiation sensing methodology outperforms the other combustion indicators in terms of variability.