The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
In the United States there are more than 230,000 total hip replacements annually, and periprosthetic femoral fractures occur in 0.1–4.5% of those patients. The majority of these fractures occur at the tip of the stem (Vancouver type B1). The purpose of this study was to compare the biomechanically stability and strength of three fixation constructs and identify the most desirable construct.Fifteen...
Stress fractures of the bowed femoral shaft (SBFs) may be one of the causes of atypical femoral fractures (AFFs). The CT-based finite element method (CT/FEM) can be used to structurally evaluate bone morphology and bone density based on patient DICOM data, thereby quantitatively and macroscopically assessing bone strength. Here, we clarify the pathogenic mechanism of SBFs and demonstrate this new...
To compare the biomechanical stability of four different kinds of percutaneous screw fixation in two types of unilateral sacroiliac joint dislocation.Finite element models of unstable Tile type B and type C pelvic ring injuries were created in this study. Modelling was based on fixation with a single S1 screw (S1-1), single S2 screw (S2-1), two S1 screws (S1-2) and a combination of a single S1 and...
Femoral neck fractures represent a relatively uncommon injury in the non-elderly population often resulting from high-energy trauma. The cornerstone of their management is anatomic reduction and stable internal fixation of the femoral neck in an attempt to salvage the femoral head. Complications including avascular necrosis of the femoral head, non-union and post-traumatic osteoarthritis are not uncommon...
We performed a simple biomechanical study to compare the fixation strength of titanium mesh with traditional tension-band augmentation, which is a standard treatment for transverse patella fractures. We hypothesised that titanium mesh augmentation is not inferior in fixation strength to the standard treatment.Twenty-four synthetic patellae were tested. Twelve were fixed with stainless steel wire and...
The relatively high complication rate after fixation of olecranon fractures has led to an increasing application of anatomically pre-contoured locking plate systems. The purpose of the present study was to conduct a biomechanical comparison of olecranon osteosyntheses by applying the Olecranon VA-LCP and the 3.5mm LCP Hook Plate (LCP, locking compression plate) to an unstable fracture model under...
The optimal treatment for avulsion-type greater tuberosity fractures is yet to be determined. Three fixation methods are tested: tension band with #2 wire suture (TB), double-row suture bridge with anchors (DR), and simple transosseous fixation with braided tape (BT).Twenty-four porcine proximal humeri were randomised into three groups: TB, DR and BT. A standardised greater tuberosity (GT) osteotomy...
The architecture of joints has potentially the greatest influence on the nature of intra-articular fractures. We analysed a large number of intra-articular fractures with two aims: (1) to determine if the pattern of injuries observed supports our conjecture that the local skeletal architecture is an important factor and (2) to investigate whether associated dislocations further affect the fracture...
Distal femur fractures proximal to total knee femoral component constitutes the most prevalent type of periprosthetic fracture, and plate fixation treatment is associated with a 7.7% incidence of refracture proximal to the plate. The primary objective of this study was to compare proximal fixation techniques of a periprosthetic distal femur fracture plate in an osteoporotic bone model. The secondary...
This manuscript will provide an overview of how the age and osteoporosis related changes in mechanical properties of bone affect the stability of osteosynthesis constructs, both from a mechanical as well as from a clinical perspective. The manuscript will also address some of the principles of fracture fixation for osteoporotic fractures and discuss applications of osteoporotic fracture fixation at...
This review will define the role of collagen and within-bone heterogeneity and elaborate the importance of trabecular and cortical architecture with regard to their effect on the mechanical strength of bone. For each of these factors, the changes seen with osteoporosis and ageing will be described and how they can compromise strength and eventually lead to bone fragility.
The current biomechanical work compares the symphyseal and sacroiliac stability obtained with two systems of bone osteosynthesis. The two methods of fixation compared were the 6-hole suprapubic non-locked plate and pubic fixation with two cannulated screws, a novel technique that can be applied percutaneously in the clinical practice. The aim of this study was to examine the validity of the use of...
High fibular spiral fractures are usually caused by pronation-external rotation mechanism. The foot is in pronation and the talus externally rotates, causing a rupture of the medial ligaments or a fracture of the medial malleolus. With continued rotation the anterior and posterior tibiofibular ligament will rupture, and finally, the energy leaves the fibula by creating a spiral fracture from anterior...
The purpose of this study was to demonstrate the strength characteristics of a hybrid uni-cortical construct for clavicle fixation. The technique reported aims to combine benefits of uni-cortical fixation with stability comparable to traditional bi-cortical fixation. The approach utilises long, oblique uni-cortical screws at the distal ends of the plate acting as surrogate bi-cortical screws. Locked...
The architecture of joints almost certainly influences the nature of intra-articular fractures, and the concavity is much more likely to fail than the associated convexity. However, local differences in periarticular bone density potentially also plays a critical role. The purpose of this study was to investigate if there was any difference in periarticular bone density in intra-articular fractures...
Both plate and intramedullary nail fixations, including straight and anatomic nails, have been clinically adopted for the treatment of displaced mid-shaft clavicle fractures. However, the biomechanical performances of these fixations and implants have not been well evaluated. This study aims to compare the construct stability, stress distribution and fracture micro-motion of three fixations based...
The distal radial fracture is a common fracture and frequently seen in geriatric patients. During the last years, volar plating has become a popular treatment option. While the application of locking screws at the distal fragment is widely accepted, there is no evidence for their use at the radial shaft.In six osteoporotic pairs of matched human cadaver radii an extra-articular model creating an AO...
Femoral neck fractures in young individuals are typically vertical shear fractures. These injuries are difficult to stabilize due to a significant varus displacement force across the hip with weight bearing. The purpose of this study was to evaluate the biomechanical stability offered by the addition of an augmented wire to conventional inverted triangle triple screw fixation for stabilizing vertical...
Autologous bone graft remains the gold standard source of bone graft. Iliac crest has traditionally been the most popular source for autologous bone graft. However, iliac crest bone graft harvesting is associated with high donor site morbidity. Bone graft harvesting from the proximal tibia has shown great potential with reported low complication rates. However, there is a paucity of biomechanical...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.