The design features of the stand-alone cable-bollard vehicle barrier system (Cable-Bollar VBS) developed for the Vermont Yankee Nuclear Power Plant (VY) to meet the design goals of the recent 10 CFR Part 73 rule changes are discussed. The design is based on the application of fundamental engineering principles to a dynamic system, recognizing that vehicle impact on a cable system is fundamentally different from vehicle impact on a bollard or other hard barrier. As such, rigorous attention is paid to cable anchor design and performance.