The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
There are a number of possible ways to define the instrumental limit of detection (LOD) figure of merit and in the present work we define four such sample test statistics and derive their probability density functions (PDFs). Although the derived PDFs were found to be irreducible integrals, they are easily evaluated via numerical integration and can be used to obtain expectation values, population...
An amperometric enzyme sensor using tyrosinase, also called polyphenol oxidase (PPO), was constructed for determination of phenolic compounds and herbicides. The enzyme was entrapped in a conducting polymer, poly 3,4-ethylenedioxythiophene (PEDT), electrochemically generated on a glassy carbon electrode. Several experimental parameters in the electropolymerisation process and working conditions were...
Vapour phase dissolution (VPD) has been used for the dissolution of high purity arsenic through acid vapours generated by aquaregia mixture, prior to trace element characterization. Trace impurities in As were determined by employing ion-exchange and volatilization methodologies for quantitative separation of the As matrix. After dissolving the As matrix through VPD procedure, sample solution in 0...
A PVC-based sensor for La 3+ ions based on N-[hexahydrocyclopentapyrol-2((1H)yl)amino]carbonyl]-4-methyl benzene sulfonamide (gliclazide) as a novel carrier was prepared. The electrode exhibits a Nernstian response for La 3+ over a wide concentration range (1.0x10 -1 -1.0x10 -6 M) with a slope of 20.1 mV per decade. The limit of detection is 8.0x10...
Fluorescent contaminants have been observed when stock solutions of phosphate buffered saline solutions at each of three pH values (2.2, 7.5, and 12.5) are analyzed after passing through commercially available filter paper. The filtrate's fluorescence was observed to exhibit a maximum signal at 440.0 nm when excited at 365 nm. Detection of trace components could have significant implications in the...
The use of organic solvents to increase metal ion determination sensitivity by atomic absorption spectrophotometry with flame is quite common. The most employed organic solvent is 4-methyl-2-pentanona (methylisobutylketone, MIBK) which optimizes sample vaporization and combustion. In this work, we present the use of a homogeneous mixture of water-ethanol-MIBK solvents (1:14:10 v/v, respectively),...
The present work describes a selective and rapid method for the determination of molybdenum with Alizarin Red S (ARS) in the presence of a water soluble polymer, poly(sulfonylpiperidinylmethylene hydroxide) (PSPMH). The ARS modified by PSPMH reacts with molybdenum(VI) in the solutions of pH 3.4-4.0 to produce a red complex. The composition of the complex is 1:4:1 mol ratio of Mo(VI): ARS:PSPMH. The...
Polyoxyethyleneglycerol triricinoleate 35 (Cremophor EL: CrEL) is a solubilization agent for hydrophobic drugs. Recently, CrEL has shown some side effects in patients. In the present work, we introduce pyrolysis-mass spectrometry (Py-MS) for the determination of CrEL in drugs and blood samples. Mass to charge (m/z) values of 89 and 138 of CrEL and 3-nitroaniline (as internal standard), respectively,...
In this study, a novel spinach (Spinacia oleracea) tissue homogenate-based biosensor for determination of oxalate in urine was developed. The biosensor was constructed by immobilizing tissue homogenate of spinach (S. oleracea) onto a high-sensitive teflon membrane of a dissolved oxygen (DO) probe. For the stability of the biosensor, general immobilization techniques were used to secure the spinach...
On the basis of the formation and pre-concentration of an α-Keggin-type [PMo 12 O 40 ] 3- complex, a novel voltammetric method was developed for the determination of trace levels of P(V). The α-[PMo 12 O 40 ] 3- complex was formed by heating a 5x10 -4 M Mo(VI)-0.2 M HCl-40% (v/v) CH 3 CN system containing...
Based on the interaction between Eriochrome Blue Black R (EBBR) and proteins, which causes a strong light-scattering signal with the maximum scattering peak located at 398 nm, a simple, rapid, sensitive and selective method is developed for the determination of proteins by the light-scattering technique using a common spectrofluoremeter. Under proper experimental conditions, the protein determination...
A chemiluminescence (CL) biosensor on a chip coupled to microfluidic system is described in this paper. The CL biosensor measured 25x45x5 mm in dimension, was readily produced in analytical laboratory. Glucose oxidase (GOD) was immobilized onto controlled-pore glass (CPG) via glutaraldehyde activation and packed into a reservoir. The analytical reagents, including luminol and ferricyanide, were electrostatically...
The analytical properties of 1-phenyl-1,2-propanedione-2-oxime thiosemi-carbazone (PPDOT) are described for the first time. The reagent gives colour reactions with copper(II) and nickel(II) in sodium acetate-acetic acid buffer medium. The copper complex shows maximum absorbance at 465 nm while the nickel complex at 395 nm. Therefore, these colour reactions have been advantageously used for the simultaneous...
A novel calix[4]arene derivative containing benzothiazole group was coated on glassy carbon electrode (GCE) and then applied to the recognition of mercury ion. Cyclic and square wave voltammetric results showed that the modified electrode selectively recognizes Hg 2+ ion in aqueous media. A new anodic stripping peak at -0.3 V (vs. Ag/Ag + ) can be obtained by scanning the potential...
Triazine herbicides form a wide group of substances that belong among the most common agrochemicals applied for pre- and post-emergence weed control. So, they can be found in the environment at trace level. In order to determine their concentrations in water samples by the usual analytical techniques, a preconcentration step is commonly necessary. In this paper, a simple analytical method for the...
A method for simultaneous analysis of V(IV) and Co(II) has been developed by using artificial neural network (ANN). This method is based on the difference of the chemical reaction rate of V(IV) and Co(II) with Fe(III) in the presence of chromogenic reagent, 1,10-phenanthroline. The reduced product of the reaction, Fe(II), can form a colored complex with 1,10-phenanthroline and make a visible spectrophotometric...
Tris(2,2'-bipyridyl)ruthenium(II) electrochemiluminescence detection in a capillary electrophoresis separation system was used for the determination of diphenhydramine. In this study, platinum disk electrode (300 μm in diameter) was used as a working electrode and the influence of applied potential and buffer conditions were investigated. Under optimal conditions: 1.2 V applied potential, pH 8.50,...
Non-chromatographic speciation approaches have been developed for determination of water-soluble and phosphate-exchangeable As(III) and As(V) in certified reference materials of coal fly ash and sediments by FI-HGAAS. A 2 IV6-2 fractional factorial design was employed for screening optimisation of the flow injection manifold. A simple two-stage sequential extraction protocol...