The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
In this study, attempts were made to present a sensitive strategy for determining rutin. To reach the goal of the study, a poly(sulfosalicylic acid) film was electropolymerized on a gold electrode, which was modified by 2-mercaptobenzothiazole self-assembled monolayer and multi-walled carbon nanotubes (PSSA/CNTs/MBT/Au). The proposed sensor was characterized by different techniques including field...
The WHO annually reports an increasing abuse of new psychoactive substances (NPS), which are a heterogeneous group of synthetic drugs and are consumed as substitute for controlled drugs of abuse. In this work, we focused on highly potent derivatives such those of phenethylamine (2C), N-2-methoxybenzyl phenethylamine (NBOMes), lysergic acid diethylamide (LSD), and fentanyl. Severe to fatal intoxications...
Non-targeted metabolomics research of human volatile urinary metabolome can be used to identify potential biomarkers associated with the changes in metabolism related to various health disorders. To ensure reliable analysis of urinary volatile organic metabolites (VOMs) by gas chromatography-mass spectrometry (GC-MS), parameters affecting the headspace-solid phase microextraction (HS-SPME) procedure...
Electro-mediated microextraction (EMM) combined with micro-high performance liquid chromatography-ultraviolet detection was successfully developed for the determination of selected phenols, namely 4-chlorophenol (4CP), 2-nitrophenol (2NP) and 2,4-dichlorophenols (2,4 DCP) in water. A solvent-impregnated agarose gel disc was utilized as a solvent holder in this study. Under optimum extraction conditions,...
Fuel quality control has gained interest in many countries owing to the potential damage of low-quality fuel to engines, the environment, and economy. Thus, the application of analytical techniques to verify quality control of fuels has become crucial. The portable micro-spectrometer in the near infrared region (microNIR) has gained credibility as a successful analytical technique in several quality...
The wine industry requires reliable methods for the quantification of phenolic compounds during the winemaking process. Infrared spectroscopy appears as a suitable technique for process control and monitoring. The ability of Fourier transform near infrared (FT-NIR), attenuated total reflectance mid infrared (ATR-MIR) and Fourier transform infrared (FT-IR) spectroscopies to predict compositional phenolic...
In this work, we report on the electrochemical behavior of bioconjugates prepared with gold nanoparticles (AuNP) capped with three different molecular layers (citrate anions, 6-mercaptopurine and ω-mercaptoundecanoic acid) and the protein hemoglobin (Hb). Freshly formed bioconjugates are deposited on a glassy carbon electrode and assayed for electroactivity. A pair of redox peaks with formal potential...
The enrichment factor (ε) is a common way to express Isotope Effects (IEs) associated with a phenomenon. Many studies determine ε using a Rayleigh-plot, which needs multiple data points. More recent articles describe an alternative method using the Rayleigh equation that allows the determination of ε using only one experimental point, but this method is often subject to controversy. However, a calculation...
The development of novel assays to detect collagen fragments is of utmost importance for diagnostic, prognostic and therapeutic decisions in various collagen-related diseases, and one essential question is to discover probe peptides that can specifically recognize target collagen sequences. Herein we have developed the fluorescence self-quenching assay as a convenient tool to screen the capability...
A novel headspace colorimetric nanosensor strategy for specific detection of Hg(II) was developed based upon analyte induced etching and amalgamation of gold nanoparticles (AuNPs). The Hg(II) was first selectively reduced to its volatile form, Hg(0), by stannous chloride (SnCl2) through chemical cold vapor generation (CVG) reaction. Then, the Hg(0) was headspace extracted into 37μL thioglycolic acid...
A stoichiometric displacement model for retention (SDM-R) of small solutes and proteins based on hydrophilic interaction chromatography (HILIC) was presented. A linear equation that related the logarithm of the capacity factor of the solute to the logarithm of the concentration of water in the mobile phase was derived. The stoichiometric displacement parameters, Z (the number of water molecules required...
The Cu2+-decorated functional mesoporous material was fabricated by thermally initiated free-radical polymerization of octavinyl polyhedral oligomeric silsesquioxane. It was used as adsorbent for highly specific separation of histidine (His)-rich proteins in blood and cell lysate based on immobilized metal affinity chromatography. The functional mesoporous material (named as PPOSS-IDA-Cu2+) was characterized...
A facile hydrothermal process was used to prepare MnCoxOy nanoparticles (NPs) in alkaline medium (pH~10.5) at room temperature. The NPs were characterized by Fourier-transform infrared spectroscopy (FTIR), ultraviolet visible spectroscopy (UV/vis), field emission scanning electron microscopy (FESEM), X-ray photoelectron spectroscopy (XPS), energy-dispersive X-ray spectroscopy (EDS), and powder X-ray...
The chemical composition of complex inorganic materials, such as copper concentrate, may influence the economics of their further processing because most smelters, and particularly the producers of high-purity electrolyte copper, have strict limitations for the permissible concentration of impurities. These components might be harmful to the quality of the products, impair the production process and...
Membrane based microfluidic devices have gained much popularity in recent years, as they make possible rapid, inexpensive analytical techniques that can be applied to a wide variety of areas. The ability to modify device hydrophilicity and hydrophobicity is critically important in fabricating membrane based microfluidic devices. Polar hydrophilic membranes, such as glass microfiber (GMF) membranes,...
In this work, a glassy carbon electrode modified with β–cyclodextrins and multi–walled carbon nanotubes (β–CDs/MWCNTs/GCE) was constructed and applied for the square-wave adsorptive stripping voltammetric (SWAdSV) determination of the pesticide dichlorophen (Dcp). For the first time, this compound was electrochemically investigated. The voltammetric measurements were conducted in phosphate buffer...
Cytochrome c (Cyt c) has been used as a model protein to investigate the characters of modified electrodes by many researchers. It has been also employed to construct biosensors to detect hydrogen peroxide, nitrate, superoxide, and etc. Cyt c immobilization techniques, including physical adsorption, entrapment in hydrogel or polymers, layer-by-layer assembly, Langmuir–Blodgett, and covalent attachment...
In this work, a rapid and straightforward method was developed for colorimetric determination of ammonia using smartphones. The mechanisms is based on the manipulation of the surface plasmon band of silver nanoparticles (AgNPs) via the formation of Ag (NH3)2+ complex. This complex decreases the amount of AgNPs in the solution and consequently, the color intensity of the colloidal system decreases...
Monitoring the concentration of blood glucose in patients is a key component of good medical diagnoses. Therefore, developing an accurate, rapid and sensitive strategy for monitoring blood glucose is of vital importance. We proposed a strategy for serum glucose determination combining 2-(4-boronobenzyl) isoquinolin-2-ium bromide chemical labeling with black phosphorus assisted laser desorption ionization-time...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.