The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
A novel microfluidic chip integrating an osmosis-based micro-pump was developed and used for perfusion cell culture. The micro-pump includes two sealed chambers, i.e., the inner osmotic reagent chamber and the outer water chamber, sandwiching a semi-permeable membrane. The water in the outer chamber was forced to flow through the membrane into the inner chamber via osmosis, facilitating continuous...
A greener and more sensitive spectrophotometric procedure has been developed for the determination of phenol and o-cresol that exploits an aqueous two-phase system (ATPS) using a liquid–liquid extraction technique. An ATPS is formed mostly by water and does not require organic solvent. Other ATPS components used in this study were the polymer, polyethylene oxide, and some salts (i.e., Li 2 ...
To our knowledge, we report the first fluorescence aptasensor for detecting human neutrophil elastase (HNE) in homogeneous solution. The biosensor contains a short DNA scrambled sequence strand (SS) complementary to part of the aptamer sequence or the loop of molecular beacon (MB). The aptamer-HNE recognition event involves competition between the molecular beacon and loose HNE aptamer for the binding...
A new method that utilizes 1-(2-aminoethyl)-3-phenylurea-modified silica gel as a solid-phase extractant has been developed for preconcentration of trace Sc(III) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions for effective adsorption of trace level of Sc(III) were optimized using batch and column procedures in detail. The optimum...
Cu nanoparticles have been electrochemically incorporated polypyrrole film that was used for modification of the glassy carbon electrode surface. The performance of the electrode has been characterized by cyclic voltammetry and atomic force microscopy. The electrode has shown high electrocatalytic activity towards the oxidation of dopamine (DA) and uric acid (UA) simultaneously in a phosphate buffer...
Electrochemical solid phase nano-extraction, a novel sample preparation technique, was used for the determination of trace iodide in iodised table salt based on the silver sulfate nanoparticle-modified carbon paste electrode. Electrochemical solid phase nano-extraction was realized in the exchange between the sulfate anion in nanoparticles and an iodide anion from aqueous solution. The released silver...
Immobilization of enzyme on detonation nanodiamond (dND, 3–10nm) and its application for efficient proteolysis have been demonstrated. By evaluation of the Michaelis constant (K m ) and maximum velocity (V max ) of immobilized enzyme, its activity was not impaired significantly by immobilization. And enzyme immobilized on dNDs exhibited much better thermal and chemical stabilities...
The π–A isotherms and UV–vis spectra of the transferred films suggested that the monolayer of p-tert-butylthiacalix[4]arene can coordinate with Hg 2+ at the air–water surface. From these observations, a glassy carbon electrode coated with Langmuir–Blodgett film of p-tert-butylthiacalix[4] arene as a new voltammetric sensor is designed for the determination of trace amounts of Hg 2+ ...
The electrochemical determinations of 4-chlorophenol (4-CP) and 4-nitrophenol (4-NP) by chronoamperometry (CA) and multiple pulsed amperometry (MPA) using expanded graphite-epoxy composite (EG-Epoxy) and rotating spectral graphite disc (SG) electrodes are reported. The electrochemical behaviours of both electrodes in the presence of organics informed about oxidation peak potential and the electrode...
Interest in tungsten occurrence and geochemistry is increasing due to increased use of tungsten compounds and its unknown biochemical effects. Tungsten has a complex geochemistry, existing in most environmental matrices as the soluble and mobile tungstate anion, as well as poly- and heteropolytungstates. Because the geochemistry of tungsten is substantially different than most trace metals, including...
The secondary metabolites of different Ephedra plants are various. Therefore, the discrimination of different Ephedra plants is significant. An objective, easy-to-use, rapid and pollution-free approach is proposed for discriminating Ephedra plants of different species, habitats and picking times on the basis of diffuse reflectance Fourier transform near infrared spectroscopy (FT-NIRS) measurements...
Atmospheric aerosol particles, collected with the particle-into-liquid sampler at SMEARII station in Finland in mid-August 2007, were analysed for biogenic acids. The sample pretreatment method, comprising solid-phase extraction with anion exchange and hydrophilic–lipophilic balance materials, was optimized. Extraction efficiencies of solid-phase extraction from 10 and 20ml samples were about 100%,...
The extraction of polybrominated diphenyl ethers (PBDEs) from SRM 2585 (Organic Contaminants in House Dust) was investigated using supercritical fluid R134a as an extraction solvent. Three methods of dust extraction were studied: (1) extraction of dry dust, (2) extraction of dry dust dispersed on Ottawa sand and (3) extraction of dust wet with dichloromethane. For each of the three sample preparation...
Despite biological variability the spectral characteristics of undiluted human urine show relatively low autofluorescence at short UV (250–300nm) excitation. However with dilution the fluorescence intensity remarkably increases. This paper examines the mechanisms behind this effect, by using excitation–emission matrices. Corrections for the inner filter effect were made for improved understanding...
UV-induced carbonyl generation with formic acid is used for gaseous sample introduction into an atomic fluorescence spectrometer for the determination of ultra-trace nickel. Compared with conventional carbonyl generation, no toxic gas CO is involved in this work, and volatile Ni(CO) 4 is generated with a single reagent formic acid under the irradiation of UV light (253.7nm, 15W). The reaction...
A new solid phase extraction method for separation and preconcentration of trace amounts of uranium, thorium, and zirconium in water samples is proposed. The procedure is based on the adsorption of U(VI), Th(IV) and Zr(IV) ions on a column of Amberlite XAD-2000 resin loaded with α-benzoin oxime prior to their simultaneous spectrophotometric determination with Arsenazo III using orthogonal signal correction...
The porous Cu film was deposited on a Pt/Ti/Si substrate by electrochemical deposition accompanied by hydrogen evolution at very high current densities. CuO films with similar morphologies were obtained by subsequent annealing of the porous copper films. The morphology, composition and structure of the porous Cu and porous CuO were investigated by FE-SEM, EDS and XRD methods. The complete transformation...
A natural biosorbent containing amine functional groups, chitosan, and a novel sorbent, chitosan-immobilized sodium silicate, were prepared and utilized for the selective sorption of As(V) from waters prior to its determination by atomic spectrometric techniques, namely, hydride generation atomic absorption spectrometry (HGAAS) and inductively coupled plasma mass spectrometry (ICP-MS). Chitosan was...
Tin octoate is used as a catalyst in the synthesis of polydimethylsiloxane (PDMS), a room temperature vulcanizing (RTV) silicone rubber. This rubber is largely used in the medical field due to its great biocompatibility. In this framework, a high-speed and costless analytical method for the determination of stannic ions, Sn(IV), in the presence of stannous ions, Sn(II), has been developed.The separation...
This paper examines specific cases in the literature where analysts using spectroscopic instrumentation report elemental concentrations that agree with information values reported in reference material certificates that are subsequently found to be incorrect.
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.