The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Arsenic compounds were quantified in the certified reference material MURST-ISS-A2 (Antarctic krill) using HPLC/ICPMS. The data should prove useful for assessing the accuracy of arsenic speciation procedures.
Tin octoate is used as a catalyst in the synthesis of polydimethylsiloxane (PDMS), a room temperature vulcanizing (RTV) silicone rubber. This rubber is largely used in the medical field due to its great biocompatibility. In this framework, a high-speed and costless analytical method for the determination of stannic ions, Sn(IV), in the presence of stannous ions, Sn(II), has been developed.The separation...
A novel method of ultrasonic probe-assisted ionic liquid dispersive liquid–liquid microextraction combined with electrothermal atomic absorption spectrometry (ETAAS) was developed for the determination of chromium(VI) species in water samples. In this procedure, the hydrophobic chelate of chromium(VI) with ammonium pyrrolidinedithiocarbamate (APDC) was extracted into the fine droplets of 1-hexyl-3-methylimidazolium...
A simple solidification of floating drop microextraction procedure for preconcentration and speciation of trace amounts of As(III) and As(V) in water samples has been proposed prior to electrothermal atomic absorption spectrometry (ETAAS). In this method, a free microdroplet of organic solvent is floated on the surface of aqueous solution while being agitated by a stirring bar placed on the bottom...
A simple and efficient method for the determination of ultra-trace amounts of inorganic mercury (iHg) and methylmercury (MeHg) in waters and fish tissues was developed using a micro-column filled with polyaniline (PANI) coupled online to flow injection-chemical vapour generation-inductively coupled plasma mass spectrometry (FI-CVG-ICPMS) system. Preliminary studies indicated that inorganic and methyl...
A novel and simple solid phase extraction (SPE)-high performance liquid chromatography (HPLC)–inductively coupled plasma mass spectrometry (ICP-MS) method was developed for determination of inorganic mercury (IHg), methylmercury MeHg and ethylmercury (EtHg) in water samples in the present work. The procedure involves pre-functionalization of the commercially available C18 SPE column with dithizone,...
A hyphenated ion-pair (tetrabutylammonium chloride—TBACl) reversed phase (C 18 ) HPLC–ICP-MS method (High Performance Liquid Chromatography Inductively Coupled Plasma Mass Spectroscopy) for anionic Rh(III) aqua chlorido-complexes present in an HCl matrix has been developed. Under optimum chromatographic conditions it was possible to separate and quantify cationic Rh(III) complexes (eluted...
Arsenic is a metalloid well known to be potentially toxic depending of its species. Lipid-soluble arsenicals (arsenolipids) are present in a wide range of biological samples in which they could play a role in the biosynthesis of organoarsenic compounds from inorganic arsenic compounds. Arsenolipids have recently attracted considerable interest. In order to gain deeper insights into the impact of arsenolipids...
The speciation of Hg in human hair was carried out with combustion-atomic absorption spectrometry for total Hg (THg) and headspace–gas chromatography–atomic fluorescence spectrometry (HS–GC–AFS) for methylmercury (MMHg).The determination of total Hg in hair was carried out with the AMA analyzer (Advanced Mercury Analyser 254). Accuracy and reproducibility were assessed on a Certified Reference hair...
The determination of seven arsenic species in seafood was performed using ion exchange chromatography on an IonPac AS7 column with inductively coupled plasma mass spectrometry detection after microwave assisted extraction. The effect of five parameters on arsenic extraction recoveries was evaluated in certified reference materials. The recoveries of total arsenic and of arsenic species with the two...
A bifunctional sorbent, (NH 2 +SH)silica, containing both amine and mercapto functionalities was prepared by modification of silica gel with 3-(triethoxysilyl)propylamine and (3-mercaptopropyl)trimethoxysilane. In addition to the bifunctional sorbent, silica gel was modified individually with the functional mercapto- and amino-silanes, and the mono-functional sorbents, namely (SH)silica and...
A non-chromatographic separation and preconcentration method for Se species determination based on the use of an on-line ionic liquid (IL) dispersive microextraction system coupled to electrothermal atomic absorption spectrometry (ETAAS) is proposed. Retention and separation of the IL phase was achieved with a Florisil ® -packed microcolumn after dispersive liquid–liquid microextraction (DLLME)...
A procedure to determine lead and zinc by anodic stripping voltammetry and copper by cathodic stripping voltammetry in natural river samples was developed and validated. Cu determination involves the adsorption of Cu complexes with 8-hydroxyquinoline (oxine) onto a hanging mercury drop electrode. All samples were studied at natural pH and following optimal conditions were found: an accumulation step...
In the present work, a simple and highly sensitive analytical methodology for determination of Tl + and Tl 3+ species, based on the use of modern and non-volatile solvents, such as ionic liquids (ILs), was developed. Initially, Tl + was complexed by iodide ion at pH 1 in diluted sulfuric acid solution. Then, tetradecyl(trihexyl)phosphonium chloride ionic liquid (CYPHOS ...
Arsenic is ubiquitous in the tissues of marine organisms and in uncontaminated environments it is dominantly present as the highly soluble and easily extractable non-toxic arsenical, arsenobetaine. However in contaminated environments, higher proportions of inorganic arsenic, which is much less soluble, are accumulated into the tissues of marine organisms, resulting in lower extraction efficiencies...
Mercury is a toxic compound that can contaminate humans through food and especially via fish consumption. Mercury's toxicity depends on the species, with methylmercury being the most hazardous form for humans. Hg speciation analysis has been and remains a widely studied subject because of the potential difficulty of preserving the initial distribution of mercury species in the analysed sample. Accordingly,...
A thiophene–coumarin hybrid molecule, (6E)-6-((thiophen-2-yl)methyleneamino)-2H-chromen-2-one (TMC) has been prepared and its single crystal X-ray structure is reported. TMC can selectively detect Cr 3+ in presence of other common cations. Both TMC and its Cr 3+ complex are well characterized by different spectroscopic techniques like 1 H NMR, QTOF-MS ES + , FTIR and...
A simple solid phase extraction system based on the applying the nickel–aluminum layered double hydroxide (Ni–Al LDH) as a nano-sorbent was developed for the speciation analysis of chromium and manganese by flame atomic absorption spectrometry (FAAS). The method is based on the fact that Cr(VI) and Mn(VII) oxyanions could be adsorbed on the Ni–Al(NO 3− ) LDH and/or exchanged with LDH...
A novel adsorbent was developed by coating Mg–FeCO 3 layered double hydroxides (LDHs) on cellulose fibre. The LDHs take up significant amount of selenite and selenate in a wide pH range with similar sorption capacities (pH 3.8–8.0 for selenite and pH 5.8–7.0 for selenate). A mini-column packed with Mg–FeCO 3 LDHs layer coated cellulose fibre particles was incorporated into a sequential...
A flow injection method of analysis has been developed for the simultaneous determination of V(IV) and V(V) using the difference in the rate of complex formation between vanadium in two different oxidation states and Xylenol Orange in acidic media. The proposed method used a spectrophotometric detector equipped with two flow cells aligned with the same optical path to yield two successive peaks per...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.