The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Ionization constants of nine quinolone antibacterials in acetonitrile-water mixtures containing 0, 5.5, 10, 16.3, 25, 30, 40, 50 and 70% (w/w) acetonitrile were obtained and assignment of these pK values to the several potentially ionizable functional groups was made. The variation of the pK values obtained over the whole composition range studied can be explained by consideration of the preferential...
A solvent extraction method for the simultaneous determination of Cu, Al, Fe and Mn by reversed phase liquid chromatography is presented. The metal chelates with 5-chloro-8-quinolinol are extracted into an acetonitrile phase with tetrabutylammonium perchlorate and ammonium sulfate as salting-out agents, followed by LC separation and determination using an ODS column. The experimental parameters such...
Routine water analysis of arsenic species requires simple, inexpensive, rapid and sensitive methods. To this end, we have developed two methods, which are based on the use of inexpensive solid phase extraction (SPE) cartridges as low pressure chromatographic columns for separation and hydride generation atomic absorption spectrometry (HGAAS) and hydride generation atomic fluorescence spectrometry...
A study of liquid chromatography/electrospray/mass spectrometry (LC/ES/MS) for the determination of methylamphetamine and related compounds (amphetamine, ephedrine, phenylpropanolamine) in human urine was undertaken. We assessed the effect of collision induced dissociation (CID) spectra generated by varying exit voltage of capillary and skimmer. The responses of ES/MS in different mobile phase and...
A method has been developed for the determination of seven arsenic species in mussel tissues by liquid chromatography-hydride generation-UV photo-oxidation and detection by inductively coupled plasma mass spectrometry. In order to determine the different species, two ion-exchange columns (anionic and cationic) were used with phosphate and nitric acid/ammonium nitrate as mobile phases, respectively...
The influence of tetrabutylammonium (TBA) as a hydrophobic charged additive of the mobile phase was investigated in a chromatographic system involving d,l-dansyl amino acids as the test solute enantiomers and immobilized human serum albumin as the chiral stationary phase. By varying the column temperature, van't Hoff plots for solute retention and enantioselectivity were performed and thermodynamic...
The development of liquid chromatography with a commercially available cyano propyl stationary phase and a 100% water mobile phase is reported. Separations were performed at ambient temperature, simplifying instrumental requirements. Excellent separation efficiency using a water mobile phase was achieved, for example N=18 800, or 75 200 m -1 , was obtained for resorcinol, at a retention...
A cortisol-binding polymer was prepared by utilising a non-covalent molecular imprinting polymerisation technique. The obtained polymer was packed in a high-performance liquid chromatography (HPLC) column; the selectivity was studied by liquid chromatography, eluting cortisol, cortisone, corticosterone, progesterone, 11-ketoprogesterone, 11α-hydroxyprogesterone, 17α-hydroxyprogesterone, cortisol 21-hemisuccinate,...
The carbon film based ring-disk dual electrodes in the thin-layer radial flow cell are used as the dual electrochemical detector (DECD) for liquid chromatography (LC) to determine the monoamine neurotransmitters. Cyclic voltammetric experiments show there has great difference in the reversibility of the oxidative reactions of dopamine and ascorbate. Therefore the ring-disk dual electrode arrangement...
Nickel-titanium (Ni-Ti) alloy electrode was used as an electrochemical detector for the analysis of underivatized amino acids in flow systems. In strong alkaline solution, an oxide film on the Ni-Ti alloy electrode surface exhibited a high catalytic activity toward the oxidation of amino acids. Cyclic voltammetry experiments confirmed that electrogenerated Ni(III)O(OH) functioned as the key redox...
Benzodiazepines are some of the most often co-abused substances in methadone treatment. Their identification in biological samples is of great importance in toxicological screening and in methadone maintenance program. The aim of this report is to describe, the analytical data making possible the identification of benzodiazepines and/or metabolites using a reversed phase liquid chromatography coupled...
A series of derivatisation reactions between p-t-butyl calix[4]arene and ethyl bromoacetate were carried out in order to prepare 1,3 diester substituted calix[4]arene. Mass spectral data, obtained from direct injection of samples, indicated that the reactions were rich in the desired product. Since the ultra violet (UV) spectra of the desired product and possible impurities are very similar, liquid...
A gradient anion exchange chromatographic technique was developed for the separation of arsenobetaine (AsB), arsenocholine (AsC), arsenite (As III ), arsenate (As V ), monomethylarsonic acid (MMAA) and dimethylarsinic acid (DMAA) in one chromatographic run. This technique used low residue ammonium carbonate buffer and the inductively coupled plasma-mass spectrometry (ICP-MS)...
The formation of Fe(III) and Fe(II) chelates with pyridylazo and thiazolylazo reagents was examined. Optimum conditions for the formation of Fe(III) and Fe(II) chelates with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) were in detail evaluated. The LC method for simultaneous separation of Fe(III) and Fe(II) ions as 5-Br-PADAP chelates was evaluated using the PEEK column with C18 e.c...
A simple and highly selective isocratic reverse-phase high performance liquid chromatography (RP-LC) method at room temperature is developed in order to determination of Cyclosporine A (CyA) and its major metabolite (AM1) in serum samples of kidney transplanted patients. The method uses a phenyl column stationary phase, acetonitrile-water-methanol 47:50:3 as mobile phase and 215 nm detector wavelength,...
Solid-phase extraction (SPE) along with reversed-phase liquid chromatography (RP-LC) was used for the simultaneous determination of Zr(IV) and Hf(IV) by means of their ternary chelates with fluoride and 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP). The conditions of SPE sorption were examined in detail: type of SPE column, volume of the sample, volume of the eluent, concentrations of...
A Suntest solar simulator with arc xenon lamp was used to irradiate pure linear alkylbenzene sulfonates (LAS) standard and some commercial LAS solutions. The ozonation treatment was carried out in a pilot plant air-lift type reactor. Kinetic degradation curves were obtained showing an apparent first order reaction in both cases. Extraction and preconcentration of samples was carried out by off-line...
If a matrix effect is detected during the validation stage of an analytical method, the standard addition methodology must be applied. To reach a good estimation of the uncertainty associated with the determination, an adequate identification and evaluation of each uncertainty source should be done. As an example to illustrate how to calculate the uncertainty in this case, the simultaneous determination...
The isocratic separation of impurities for a stavudine synthesis control has been studied by liquid chromatography (LC). The investigations have shown that isocratic reversed-phase LC conditions were unable to achieve a good separation. It was established that isocratic normal-phase LC system with common silica column as a stationary phase and the mixture of ethyl acetate with 4% (v/v) of ethylene...
Liquid chromatographic method has been developed, based on precolumn derivatization of vanadium(V) with 2-acetylpyridine-4-phenyl-3-thiosemicarbazone (APPT). The complex is extracted in chloroform together with palladium(II), tin(II) and iron(III) and eluted and separated completely from Kromasil 100 C-18, 10μm (25cm×4.6mm i.d.) column with methanol:water:acetonitrile (60:30:10, v/v/v) with a flow...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.