The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
A hydride generation system combined with high-resolution inductively coulped plasma mass spectrometry was used to determine tin in marine materials. The optimization conditions for determination of tin in this system are 0.015 M of sulfuric acid solution as medium, 0.2% (w/v) of sodium tetrahydroborate(III) in 0.015 M of sodium hydroxide solution as a reductant and argon as the carrier gas at a flow...
A method for the determination of Mo, U and B in waters by inductively coupled plasma mass spectrometry, using an electrothermal vaporizer for sample introduction, is described. For Mo and U, NH 4 F was chosen as modifier and for B, synthetic sea water plus mannitol were used. The modifier effect was verified and the optimized pyrolysis and vaporization temperatures were obtained from pyrolysis...
A method was developed for the determination of rare earth impurities in high purity Gd 2 O 3 by inductively coupled plasma mass spectrometry (ICP-MS). The matrix suppression effect of Gd 2 O 3 on signals of rare earth impurities was compensated for by Re internal standardization. The spectra overlap interferences from GdH, GdO, GdOH n (n=1–3) on Tb, Tm, Yb...
A method has been developed for the determination of seven arsenic species in mussel tissues by liquid chromatography-hydride generation-UV photo-oxidation and detection by inductively coupled plasma mass spectrometry. In order to determine the different species, two ion-exchange columns (anionic and cationic) were used with phosphate and nitric acid/ammonium nitrate as mobile phases, respectively...
Accurate determinations of the platinum group elements (PGEs) and gold, known as the precious metals, have always been difficult tasks. The metals are often present at trace levels in sample types of complex composition. This situation has improved recently due to developments of instrumental methods and their applications to analyses of the precious metals in a variety of matrices. Attention has...
A method developed to determine organic and inorganic selenium species in human urine samples is presented in detail. After a simple sample treatment based on elimination of non-charged organic compounds, selenium species were separated by high performance liquid chromatography (HPLC) on a Spherisorb 5 ODS/AMINO column using two different chromatographic conditions: phosphate buffers at pH 2.8 and...
The mandate assigned by the European Union to the Community Reference Laboratory for residues at the Istituto Superiore di Sanita covers, among other things, the assessment of trace elements in living animals as well as their products. To better protect the health of the consumer, this task aims in particular at harmonizing the procedures in use at the National Reference Laboratories (NRLs) for residues...
A microwave assisted digestion procedure has been developed for dissolution of fly ash samples prior to the inductively coupled plasma-mass spectrometric determination of their elemental composition. The developed methodology was validated by carrying out the analysis of two high-silicate containing reference materials (CRM 134R sewage amended soil and NIES JR 1 rock) and by means of the comparison...
Trace amounts of heavy metals in the ice cores from Canadian Arctic were analyzed using inductively coupled plasma mass spectrometry (ICP-MS). A custom made plastic device and ceramic knives were used to remove the contamination on the ice core surface. Ice cores could be broken into small sections (2-3 cm thick) after decontamination with the plastic device and ceramic knives. High-resolution depth...
A rapid and simple method has been developed for the separation of chromium (III) and Cr(VI) species in river and reservoir water. Chromium (III) can be chelated with 8-hydroxyquinoline immobilized polyacrylonitrile (PAN) fiber, whereas Cr(VI) cannot. Chelated Cr(III) can be eluted with 2 mol l -1 HCl-0.1 mol l -1 HNO 3 . Cr(VI) in the filtrate and Cr(III) in the...
A new method for determining ultra-trace levels of hexavalent chromium in ambient air has been developed. The method involves a 24-h sampling of air into potassium hydroxide solution, followed by silica gel column separation of chromium (VI), then preconcentration by complexation and solvent extraction. The chromium (VI) complex was dissolved in nitric acid. The resultant chromium ions were determined...
A method is developed for determination of trace elements, including Ag, As, Cd, Co, Cr, Cu, Mn, Ni, Se, Tl and Zn, in fish otoliths by electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS). Hydrofluoric acid was used to precipitate calcium resulting from acid dissolution of otolith calcium carbonate. Initial acidity of the sample solution influenced the precipitation...
Element determination in solid waste products from the steel industry usually involves the time-consuming step of preparing a solution of the solid. Laser ablation (LA) inductively coupled plasma mass spectrometry (ICP-MS) has been applied to the analysis of Cr, Ni, Cu, As, Cd and Sn, elements of importance from the point of view of their impact on the environment, in electric arc furnace flue dust...
A microwave digestion method with HNO 3 alone was conducted at a temperature as high as 250°C for determination of 19 trace elements (Li, Be, V, Cr, Mn, Co, Ni, Cu, Zn, Ga, As, Se, Rb, Sr, Cd, Cs, Ba, Hg, and Pb) in coal jointly by inductively coupled plasma optical emission spectrometry (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS), and flow injection ICP-MS (FI-ICP-MS)...
Metal speciation analysis in MTs was carried out in two tropical fish species of Brazil, the freshwater fish pearl cichlid (Geophagus brasiliensis) and the marine fish white sea catfish (Netuma barba), that are presently used to monitor the effects of heavy metal pollution in aquatic ecosystems in Brazil. In order to obtain the MT fraction, liver cytosols from both fish species where subjected to...
Rh is contained in catalyst in much smaller quantities than Pt. For this reason, the database for this metal with respect to emissions from catalytic converters is much smaller than that for platinum, thus precluding a quantitative risk assessment.Accurate determinations of the rhodium have always been difficult tasks. The metal is often present at trace levels in sample types of complex composition...
A methodology for bulk analysis of Al and Ti and for determination of soluble and total Al and Ti concentration in steel samples by laser ablation inductively coupled plasma mass spectrometry was developed. The spatial distribution (both at surface and within the sample) of the insoluble fraction of Al and Ti was also qualitatively estimated. Certified reference materials (CRMs) SS-451 to 460 (carbon...
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been applied to multi-element determination in compost samples. Since compost is a heterogeneous mixture of organic and inorganic materials, the influence of sample heterogeneity on the accuracy and precision of analysis was investigated. Several parameters related to the following were studied: laser (energy, laser-beam diameter,...
A newly synthesized alkyl phosphinic acid resin (APAR) was used for on-line preconcentration of trace rare earth elements (REES, lanthanides including yttrium) and then determined by inductively coupled plasma mass spectrometry. REEs in seawater could be on-line concentrated on the APAR packed column (4.6mm i.d.×50mm in length), and eluted from the column with 0.5mL 0.1molL −1 nitric acid...
The determination of 52 impurity elements in niobium materials (niobium metal, niobium oxide (V), and niobium pentaethoxide) was performed by inductively coupled plasma mass spectrometry (ICP-MS) with on-line anion exchange matrix separation as well as direct nebulization. Niobium material samples were decomposed with a mixture of hydrofluoric acid and nitric acid to prepare 10% niobium solutions...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.