The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
A method for the direct determination of ATP that exhibits reasonable sensitivity, and responds to very few interferants, has been developed. The chelation-enhanced fluorescence between N-(anthracen-9 -yl methyl)tris(3-aminopropyl)amine and adenosine 5 -triphosphate is utilized in this determination. The method was tested in batch and flow-injection analysis (FIA) modes. The typical detection...
A flow-injection manifold is proposed for determination of nitrite based on the reaction with 3,6-diamino acridine (proflavin sulfate) in hydrochloride acid medium. The assembly is adapted for nitrate determination by including a reductive column filled with copperized cadmium. The influence of foreign substances is also studied. The method gives a linear calibration graph over the range 0 06-4mg...
A simultaneous flow-injection analysis (FIA) manifold that could analyse three ions from a single injection was designed, constructed, calibrated and used successfully to analyse Li + , Na + and K + . This FIA method was 10 times faster than the batch technique. The sample volume required was a fraction of about 1 to 1 that technique. The outputs were quite reproducible...
CP-93,393 is a drug candidate at Pfizer. Flow-injection analysis-mass spectrometry (FIA-MS) was used to monitor reaction completion for CP-93,393 reaction mixtures. FIA-MS provides essentially instantaneous results, is relatively simple to operate, and is a universal system that can be used to monitor any reaction as long as the product has a molecular weight that differs from the molecular weights...
Speciation of elements in natural matrices, especially of trace metals, is one of the predominant development trends of modern inorganic analysis. The main part of the conventional speciation procedures is a suitable combination of separation and chemical conversion steps, for which the most appropriate methodology seems to be the use of flow-injection. A shorter time of performance of these operations...
The specificity of enzymes is often not sufficient to simultaneously determine two parent substrates in a given matrix. Approaches to enhance the selectivity by applying the principle of an array arrangement to flow-injection analysis (FIA) systems based on several immobilized isoenzymes are successful. Immobilized enzymes and detectors in FIA systems often suffer from interferences from impurities...
An automated flow-injection method for determination of primary aromatic amines based on the Bratton-Marshall reaction is described. This method is used for analysis quality control of three different X-ray contrast media (Omnipaque ® , Imagopaque ® and Visipaque ® which are viscous solutions. In flow-injection analysis, such samples cause refractive index effects and low....
Addition of diethylenetriaminepentaacetic acid (DTPA) to the fluorescent binary complex of thorium and 8-hydroxyquinoline-5-sulfonic acid (HQS) forms the Th-DTPA-HQS fluorescent ternary complex. The formation of this ternary complex enhances the selectivity for the determination of thorium. Excesses of DTPA and HQS are used as reagents in flow-injection analysis to detect thorium. The excess DTPA...
Chemical analysis of surface active species (surfactants) is of interest for many applications, such as in process monitoring, biomedical applications, environmental monitoring and surface science investigations. Recently, we reported a dynamic surface tension detector (DSTD) based upon optically probing the size of a repeating drop resulting from constant flow of an aqueous solvent out of the end...
A lot of modern analytical strategies for exploiting chemistries have been developed by using flow-injection analysis. However, even after 20 years of flow-injection evolution, there still are new quantitative procedures being established using old qualitative assays. The formation of Prussian Blue is a classical test to detect Fe 2+ using hexacyanoferrate(III) as a precipitating reagent....
An automatic direct spectrophotometric method for the simultaneous determination of nitrite and nitrate by flow-injection analysis has been developed. Nitrite reacts with 3-nitroaniline in the presence of hydrochloric acid (0.96-1.8 M HCl or pH 0.5-0.7) to form a diazonium cation, which is subsequently coupled with N-(1-naphthyl)-ethylenediamine dihydrochloride to form a stable purple azo dye, the...
A flow-injection analysis (FIA) method for the ultraviolet spectrophotometric determination of copper in copper ores is described. The ore samples are dissolved in concentrated perchloric acid, the excess acid is neutralized with ammonia solution, and the resulting solution is used for the determination of copper. The UV-FIA system is based on the reaction of copper (II) ions with pyrophosphate and...
We have studied the speciation of chromium (VI) in stainless-steel welding dusts. The approach used for the analysis of Cr(VI) and total Cr relies on a flow-injection analyzer (FIA) equipped with two different sequential detectors. The system measures Cr(VI), by colorimetry (with 1,5-diphenyl carbohydrazide) and total chromium content by flame atomic absorption spectroscopy (AAS). The extraction...
A flow-injection system with an immobilized enzyme reactor is proposed for the determination of l-phenylalanine. Phenylalanine dehydrogenase from Rhodoccus sp. M4 was immobilized on tresylated poly (vinyl alcohol) beads (13 μm) and packed into a stainless-steel column (5 cm 4 mm i.d.). Serum sample was deproteinized with tungstic acid and filtered through an ultrafiltration membrane. The sample...
A flow-injection analytical method for the determination of hydrochlorothiazide is presented. The method is based on the chemiluminescence reaction of hydrochlorothiazide with cerium(IV) in sulphuric acid, sensitized by the fluorescent dye rhodamine 6G. The proposed procedure allows quantitation of hydrochlorothiazide in the concentration range of 0.33–130 μmol l −1 with a detection limit...
A flow-injection configuration based on a dual-phase gas-permeation system from a liquid donor to a gas acceptor stream with a thermistor flow-through detector is proposed for the direct analysis of the gas in the acceptor. This system was applied for the determination of carbon dioxide (in the form of carbonate) using the following chemical reaction: CO 2 (g)+2NH 3 (g)+H 2 ...
A novel chemiluminescence (CL) system for ammonium ion combined with flow-injection analysis is presented in this paper. It is based on the CL reaction between luminol, immobilized electrostatically on an anion-exchange column, and chlorine electrochemically generated on-line via a platinum electrode from hydrochloric acid in a coulometric cell. Ammonium ion reacts with chlorine and decreases the...
With the intention of combining partition chromatography and membrane techniques, we succeeded in developing the chromatomembrane cell which has proved to be reliable as an extraction and preconcentration manifold in flow injection analysis. With this technique, two immiscible phases can be induced to flow independently through a block of biporous (macro and micro) PTFE in order to promote analyte...
An automated flow-injection system combining a pyruvate oxidase reaction and chemiluminescence for the detection of phosphate ion in river water has been developed. In this research, we used pyruvate oxidase G (PyrOxG), from Aerococcus viridans, immobilizing it on N-hydroxysuccinicacidimido beads without a cross-linker. In this sensor system, which was constructed as a trial system of desktop type,...
An automated system with a C 18 bonded silica gel packed minicolumn is proposed for spectrophotometric detection of arsenic using flow-injection hydride generation following sorbent extraction preconcentration. Complexes formed between arsenic(III) and ammonium diethyl dithiophosphate (ADDP) are retained on a C 18 sorbent. The eluted As-DDP complexes are merged with a 1.5%...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.