The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
A poly[styrene-co-(divinylbenzene)] resin (XAD-4) functionalized with 1-hydrazinophthalazine ligand has been prepared and its analytical properties investigated. The pH dependence of sorption of metal ion on the resin has been determined for Cu(II), Ni(II), Co(II), Zn(II), Cd(II), Pb(II), Fe(III) and Cr(III). Trace amounts of these metal ions were quantitatively retained on the resin and recovered...
A macroporous resin containing iminodiacetic groups (Lewatit) was investigated for its sorption properties towards proton and nickel(II) and cadmium(II). Different compositions of the aqueous phase, and different temperatures were examined. The stoichiometry, the exchange coefficients and the intrinsic constants of the sorption equilibria were obtained from the experimental data by using the Gibbs-Donnan...
The main difficulties of trace metals analysis in estuarine and seawater stem from their very low concentration (μg/l to sub-μg/l), and, by contrast, the high salt content (up to 38 g/l in the Mediterranean Sea). ICP-MS allows multi-elemental analysis and offers great sensitivity, but may be strongly affected by matrix effects induced by high salt contents (> 1 g/l). To perform trace metals analysis...
A new chelating resin is prepared by coupling Amberlite XAD-2 with pyrocatechol through an azo spacer, characterized (by elemental analysis, IR and TGA) and studied for preconcentrating Cd(II), Co(II), Cu(II), Fe(III), Ni(II) and Zn(II) using flame atomic absorption spectrometry (FAAS) for metal monitoring. The sorption is quantitative in the pH range 3.0-6.5, whereas quantitative desorption occurs...
A polystyrene divinyl benzene (8%) copolymer has been functionalized by coupling it through N N group with 2-naphthol-3,6-disulfonic acid (NDSA). The resulting resin has been characterized by elemental analysis, thermogravimetric analysis and infrared spectra. The hydrogen ion, water regain and metal ion capacities of the resin have been determined. Two forms of chromium show different exchange...
A chelating type ion exchange resin (Amberlite IRC-718), containing iminodiacetate groups as active sites, has been characterized regarding the sorption and subsequent elution of Cd, Zn and Pb, aiming to metal preconcentration from solution samples of different origins. The methodology developed is based on off-line operation employing mini columns made of the sorbent. The eluted metals were determined...
A new chelating resin was synthesised by the modification of styrene-divinylbenzene (2%) copolymer and incorporation of dithiocarbamate groups. The polydithiocarbamate resin was characterised by elemental analysis, thermal studies and IR studies. The analytical characteristics of the sorbent were established and optimum sorption conditions for Cu, Ni, Pb, Fe, As and Mn determined. The total sorption...
A commercial cation exchange resin Amberlite 200 has been modified after immersion in solutions of polyethyleneimine (PEI). The kinetic of fixation of the metallic ions have been determined. The modification of the surface of the resin deals with a change in the order of the affinities of the resins towards cations. The retention is the function of the formation and the stability of the complex. The...
A new method has been developed using (bis-3,4-dihydroxy benzyl)p-phenylene diamine functionalized to XAD-16 (a polystyrene divinyl benzene copolymer) matrix, to preconcentrate mainly U(VI) and Th(IV) from synthetic and real samples. The developed method is free from matrix interference due to alkali and alkaline metal ions and preconcentrates the actinides with a high degree of selectivity, with...
A new chelating resin based on chitosan biopolymer modified with 5-sulphonic acid 8-hydroxyquinoline using the spray drying technique for immobilization is proposed. The chelating resin was characterized by thermogravimetric analysis (TGA) and X-ray diffraction (XRD) and surface area by nitrogen sorption. The efficiency of the chelating resin was evaluated by the preconcentration of metal ions Cu(II)...
A new stable chelating resin was synthesized by incorporating the bis(2-benzimidazolyl methyl)amine into Merrifield polymer through CN covalent bond and characterized by elemental analysis, IR and thermal study. The sorption capacity of the newly formed resin for Ag(I), Cu(II), Fe(III), Hg(II) and Pb(II) as a function of pH have been studied. The resin exhibits no affinity for alkali or alkaline...
A chelating resin, pyrocatechol violet (PV) immobilised on an Amberlite XAD-1180 support, was prepared and its use for the atomic absorption spectrometric determination of aluminium was investigated. The XAD-1180-PV resin was characterised by infrared spectrometry and thermal gravimetric analysis. The optimum pH value for quantitative sorption is 8–9, and desorption can be achieved by using 5.0–10...
2-{[1-(3,4-Dihydroxyphenyl)methylidene]amino}benzoic acid (DMABA) was loaded on Amberlite XAD-16 (AXAD-16) via azo linker and the resulting resin AXAD-16-DMABA explored for enrichment of Zn(II), Mn(II), Ni(II), Pb(II), Cd(II), Cu(II), Fe(III) and Co(II). The optimum pH values for extraction are 6.5–7.0, 5.0–6.0, 5.5–7.5, 5.0–6.5, 6.5–8.0, 5.5–7.0, 4.0–5.0 and 6.0–7.0, respectively. The sorption capacity...
On-line preconcentration system for the selective, sensitive and simultaneous determination of chromium species was investigated. Dual mini-columns containing chelating resin were utilized for the speciation and preconcentration of Cr(III) and Cr(VI) in water samples. In this system, Cr(III) was collected on first column packed with iminodiacetate resin. Cr(VI) in the effluent from the first column...
Amberlite XAD-16 was loaded with 4-{[(2-hydroxyphenyl)imino]methyl}-1,2-benzenediol (HIMB) via azo linker and the resulting resin AXAD-16-HIMB explored for enrichment of Zn(II), Mn(II), Ni(II), Pb(II), Cd(II), Cu(II), Fe(III) and Co(II) in the pH range 5.0–8.0. The sorption capacity was found between 56 and 415μmolg −1 and the preconcentration factors from 150 to 300. Tolerance limits for...
An integrated approach for the accurate determination of total, labile and organically bound dissolved trace metal concentration in the field is presented. Two independent automated platforms consisting of an ultraviolet (UV) on-line unit and a chelation/preconcentration/matrix elimination module were specifically developed to process samples on-site to avoid sample storage prior to inductively coupled...
A new chelating resin containing bis[2-(2-benzothiazolylthioethyl)sulfoxide] was synthesized using chloromethylated polystyrene as material and characterized by elemental analysis and infrared spectra. The adsorption capacities of the newly formed resin for Hg 2+ , Ag + , Cu 2+ , Zn 2+ , Pb 2+ , Mn 2+ , Ni 2+ , Cd 2+ and Fe 3+ ...
On-line preconcentration and determination of transition and rare-earth metals in water samples was performed using a Multi-Auto-Pret system coupled with inductively coupled plasma-atomic emission spectrometry (ICP-AES). The Multi-Auto-Pret AES system proposed here consists of three Auto-Pret systems with mini-columns that can be used for the preconcentration of trace metals sequentially or simultaneously,...
The application of inductively coupled plasma atomic emission spectrometry (ICP-AES) to the forensic sample was studied. On-line collection/concentration method of the sample with chelating resin column (TE-05) and air-sandwiched method to isolate the analyte zone at the highest concentration of an eluent was coupled with ICP-AES. The limits of detection (LODs) were much improved to 35 fold (Co):...
Near-infrared spectroscopy (NIRS) has been proved to be a powerful analytical tool and used in various fields, it is seldom, however, used in the analysis of metal ions in solutions. A method for quantitative determination of metal ions in solution is developed by using resin adsorption and near-infrared diffuse reflectance spectroscopy (NIRDRS). The method makes use of the resin adsorption for gathering...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.