The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
A method for rapid extraction and determination of some crown ethers in aqueous matrices using octadecyl-bonded silica membrane disks and gas chromatography is presented. Extraction efficiency and the influence of vacuum pressure, pH, and type and least amount of eluting solvent used to extract the crown ethers from the membrane disks were evaluated. Extraction efficiencies > 95% were obtained...
3-Hydroxy-2-methyl-1,4-naphthoquinone-immobilized silica gel has been used for the adsorption and estimation of copper, cobalt, iron and zinc by both batch and column techniques. The distribution coefficient D determined for each metal ion was as follows (ml g -1 ): Fe, 3.6 10 2 ; Cu, 3.9 10 2 ; Co, 3.8 10 2 ; Zn, 4.1 10 2 . Methods have been...
A novel and expeditious approach for direct determination of phenols in water and waste waters based on solid-phase extraction coupled on-line to a flow injection analysis (FIA) manifold is described. The method employs on-line preconcentration of the phenols in an acidified sample (pH=2.0) onto a 3 cm×3 mm column packed with Amberlite XAD-4 resin. The phenols are subsequently eluted from the resin...
High performance liquid chromatography (HPLC) combined with solid-phase extraction was reported on, for simultaneous analysis of pesticides in this work. The separation of 12 pesticides was achieved on a C 18 capillary column with gradient elution. Sub-microlitre injection volume of the samples and a U-shaped 35 nl flow cell were used to improve the separation and detection. In addition,...
A system for separation of zinc traces from large amounts of cadmium is proposed in this paper. It is based on the solid-phase extraction of the zinc in the form of thiocyanate complexes by the polyurethane foam. The following parameters were studied: effect of pH and of the thiocyanate concentration on the zinc extraction, shaking time required for quantitative extraction, amount of PU foam necessary...
For the first time, solid-phase extraction (SPE) has been combined to room-temperature phosphorimetry (RTP) to determine the 16 polycylic aromatic hydrocarbons related as major pollutants by the US Environmental Protection Agency (EPA). These include naphthalene, anthracene, acenaphthylene, acenaphthene, fluorene, fluoranthene, benzo(a)anthracene, benzo(k)fluoranthene, benzo(b)fluoranthene, benzo(a)pyrene,...
A solid-phase extraction (SPE) method for sample clean-up followed by a reversed-phase high-performance liquid chromatography (HPLC) procedure for the assay of five antidepressant drugs (trazodone, doxepin, desipramine, maprotiline and imipramine) is reported. The drugs were recovered from plasma buffered at a suitable pH using C18 Bond-Elut cartridges and mixtures of methanol-aqueous buffer as washing...
This article presents considerable improvements in SPE-RTP methodology for the analysis of polycyclic aromatic hydrocarbons in water samples. Bulky glassware and vacuum pump were removed from the previous extraction procedure [E.D. Hagestuen, A.D. Campiglia, Talanta 49 (1998) 547] by processing 10 ml of sample with syringes and stainless steel filter holders. The oven-drying step was substituted by...
Peptide mapping has been widely used for the identification of modified proteins involved in certain diseases. Despite the fact that capillary electrophoresis (CE) has been shown to be a powerful tool for the separation and detection of tryptic peptide fragments after protein digestion, this technique lacks sensitivity for mapping proteins isolated in very small quantities from biological samples...
A chlorphenamine-imprinted polymer was prepared in this study. Chromatographic analysis showed that the retentivity and selectivity of the imprinted polymer were greatly strengthened through molecular imprinting. As a consequence, chlorphenamine could be easily separated from diphenhydramine. Ionic interaction was proved to be the main power for the imprinted polymer to bind chlorphenamine. The strong...
The analytical potential of solid-phase extraction and room temperature fluorimetry for screening polycylic aromatic hydrocarbons in water samples is evaluated. Solid-phase extraction was performed via a syringe procedure previously reported (Talanta 52 (2000) 727). The simplicity of fluorescence measurements on the solid substrate is equivalent to solution measurements. Since oxygen quenching of...
An isolating method using a solid-phase extraction (SPE) ISOLUTE(R) C8 endcapped syringe-column for routine monitoring of residual tetracyclines (TCs) (oxytetracycline (OTC), tetracycline (TC), chlortetracycline (CTC), and doxycycline (DC)) in cow's milk is presented. In the simplest and most environmentally harmless method, milk samples could be applied directly to the SPE column, following which...
In this study, the use of syringe filled with sorbent for the separation and enrichment of bismuth, lead and nickel prior to their analysis by graphite furnace atomic absorption spectrometry was described to substitute for batch and column techniques. The method proposed in this paper was compared with column technique with respect to easiness, fastness, simplicity, recovery and risk of contamination...
2-Phenylbenzimidazole-5-sulphonic acid (PBS) is an UV-filter contained in many cosmetics as a sunscreen. A direct, selective and sensitive method to determine traces of PBS is presented. The on-line separation of this compound from urine matrix was directly coupled with fluorimetric detection in a sequential-injection system. The separation was performed using a SAX microcolumn in which the analyte...
Lead and nickel were concentrated and separated after sorbing on Chromosorb-107 filled in a syringe prior to their determination by electrothermal atomic absorption spectrometry. To retain the analytes, the sample solution treated with or without ammonium pyrolidine dithiocarbamate (APDC) was drawn into the syringe filled with Chromosorb-107 and discharged back manually. Then the analyte elements...
Solid-phase extraction (SPE) along with reversed-phase liquid chromatography (RP-LC) was used for the simultaneous determination of Zr(IV) and Hf(IV) by means of their ternary chelates with fluoride and 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP). The conditions of SPE sorption were examined in detail: type of SPE column, volume of the sample, volume of the eluent, concentrations of...
The optimum procedures for clean up aerosols in silica solid-phase extraction (SPE) cartridge prior to the analysis of polynuclear aromatic hydrocarbons (PAHs) by gas chromatography-mass spectrum (GC-MS) in selected ion monitoring detection mode have been investigated. The silica SPE cartridge is activated by dichloromethane and hexane, and then dried up by vacuum in SPE instrument for about 5 min...
A highly selective and sensitive anodic stripping differential pulse polarographic method has been developed for the determination of trace amount of bismuth in various samples after adsorption of its 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complex on amberlite XAD-2 resin in the pH range of 2.0-3.0. The retained analyte on the resin recovered with 10.0ml of 2M hydrochloric acid and bismuth...
A HPLC method with automated column switching and UV-diode array detection is described for the simultaneous determination of Vitamin D 3 and 25-hydroxyvitamin D 3 (25-OH-D 3 ) in a sample of human plasma. The system uses a BioTrap precolumn for the on-line sample cleanup. A sample of 1ml of human plasma was treated with 2ml of a mixture of ethanol-acetonitrile (2:1 (v/v))...
This work assesses for the first time the potential of natural Kaolinite as adsorptive material for preconcentration of metal traces. Manganese is quantitatively retained by 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) on thermal modified Kaolinite by column method in pH range of 8.5–10.0 at flow rate of 2mlmin −1 . Manganese was removed from column with 5.0ml of H 2 ...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.