The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper deals with the modelling of the rebar corrosion kinetics in unsaturated concrete cover. The concrete is assumed carbonated resulting in an active corrosion of steel. The corrosion kinetics is coupled with the ionic transport processes. Free corrosion in different concretes is studied in terms of ambient relative humidity. The numerical results obtained by the finite volume method are discussed and compared with a reported experiment performed on a carbonated concrete.