The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Earlier findings showed that the effects of moisture (liquid or free water) in hardened concrete on its behavior, especially the lesser known effects ofuneven moisture distribution, can (a) be significant, and (b) vary from property to property. This distribution, for instance whether or not the surface layer is drier than the overall average moisture content, can be characterized by the difference...
The results presented in this communication show that the conventional configuration adopting a shear vertical wave at 45° of incidence to detect cracks breaking the surface opposite the one on which the inspecting transducer is placed is not optimal when the crack depth is of the order of one wavelength of the inspecting wave or smaller. Angles of incidence proximal to the critical angle of longitudinal...