The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
In this paper we present a set of tuning rules for standard (integer-order) PID and fractional-order PID controllers. Based on a first-order-plus-dead-time model of the process, the tuning rules have been devised in order to minimise the integrated absolute error with a constraint on the maximum sensitivity. The achieved performance indexes can also be used for the assessment of the controller performance...