A simple water-soluble aldehyde functionalized chromone 5 was utilized as a doubly activated Michael acceptor type of chemodosimeter for cyanide in water. The water solubility of the probe 5 is due to the incorporation of two glycerol units on the starting prepared chemodosimeter. This sensory system is able to selectively distinguish cyanide among fluoride and many other anions at micromolar concentrations and instantly detect cyanide in water at ambient temperatures with a detection limit down to 1.0 mM. Thus, the chemodosimeter 5 was applied to the quantitative determination of cyanide anion in drinking water sample (drinking water from commence).