The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
A simplified analytical model is developed to study the year round effectiveness of a recirculation type earth air heat exchanger coupled with a greenhouse located in IIT Delhi, India. The performance of the system was evaluated in terms of thermal load leveling and coefficient of performance. Calculations were done for typical winter and summer day in year 2002. Temperatures of greenhouse air were...
The potential of using the stored thermal energy of ground for space heating has been investigated with the help of two buried pipe systems, i.e., ground air collector and earth air heat exchanger, integrated with the greenhouse located in the premises of Indian Institute of Technology, Delhi, India. The total length of the buried pipes in both the arrangements was kept same for making a comparative...