The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The authors analysed a proportional valve with electrical position feedback for its failure behaviour. Several failures were introduced into the feedback loop, especially into the 2 solenoids and the inductive position transducer. The behaviour of the valve for square and ramp reference signals was recorded and systematically analysed. It was shown that failures could be detected by monitoring the...
German employers’ liability insurance associations or Berufsgenossenschaften (BGs)—institutions for statutory accident insurance—maintain a measurement system for hazardous substances, the so-called BGMG. The aim of the BGMG is to determine and document valid results of measurements of exposure primarily for prevention purposes. The data are collected systematically, in parallel to the sampling in...
Part of the Polish-Swedish OSHMAN project was carried out in a textile company. It aimed at implementing and improving effective health and safety management with workers’ active involvement at all levels of the enterprise. The two main problems to be solved during the project were decreasing occupational risk and improving workers’ poor knowledge on occupational risk. Training courses, workshops...
Background. The purpose was to study the test-retest reliability and internal consistency of questions in a questionnaire concerning working conditions and health and the inter-rater reliability of observations and measurements according to an ergonomic checklist. Method. Fifty-seven operators participated in a retest questionnaire and 58 operators participated in an inter-observer test. Results....
The aim of this study was to investigate the work ability in ageing workers suffering from osteoarthritis (OA), coronary heart disease (CHD) or hypertension (H). One hundred and sixty-six OA and 355 CHD/H outpatients were evaluated. The Work Ability Index (WAI) served for work ability assessment. Patients’ results were compared with the results of a control group of 225 healthy young workers. Statistical...
This study investigated workers’ perceptions of workplace safety in an African work environment, specifically in Ghanaian work places. Workers’ safety perceptions were examined with Hayes et al.’s. (1998) Work Safety Scale. Comparative analyses were done between high- and low-accident groups, and t tests were employed to test for differences of statistical significance. Relative to their colleagues...
The development of an effective safety culture is essential to promote safe operations. Previous studies have either identified the characteristics of effective safety culture analytically, inferring them from signs and symbols derived from working practices, or have restricted the study of the development of safety culture to workers within an organisation. This paper describes a large-scale survey-based...
The aim of this work is to analyse Maximum Admissible Concentration (MAC) values proposed for irritants by the Group of Experts for Chemical Agents in Poland, based on the RD50 value. In 1994–2004, MAC values for irritants based on the RD50 value were set for 17 chemicals. For the purpose of the analysis, 1/10 RD50, 1/100 RD50 and the MAC/RD50 ratio were calculated. The determined MAC values are within...
A thermal wave skin model incorporating surface heat flux from a skin simulant sensor is developed to characterize the thermal performance of heat resistant fabrics covering the skin simulant sensor. Comparisons of time to 2nd-degree skin burn and temperature elevation of skin beneath a layer of fabric between the Pennes’ equation and the newly developed thermal wave skin model are performed in this...
All oil and gas pipeline systems are run by human operators (called controllers) who use computer-based workstations in control rooms to “control” pipelines. Several human factor elements could contribute to the lack of controller success in preventing or mitigating pipeline accidents/incidents. These elements exist in both the work environment and also in the computer system design/operation (such...
Europe is the only region in the world with common legislative acts regulating exposure to electromagnetic fields (EMF) for both the general public and workers. Council Recommendation 1999/519/EC deals with the limitation of exposure of the general public to EMF (0 Hz—300 GHz). Directive 2004/40/EC regulates the minimum health and safety requirements regarding the exposure of workers to the risks...
With the increased use of electric and electronic equipment in our offices, our daily exposure to electromagnetic fields has become increasingly complex due to the great variety of the frequency content of the fields. Today focus has shifted from monitors as the dominating sources of electromagnetic fields to other electronic equipment, cabling, nearby substations, power lines and stray currents in...
The rapid growth of mobile communications has not only led to a rising number of mobile telephones. It has also made base stations essential for services widespread on many roofs. However, not everyone is aware that working close to sources of high frequency electromagnetic fields (EMF), such as transmitter antennas for mobile phones, pagers and police, fire and other emergency services, can result...
Basic principles of reducing exposure to electromagnetic fields are reviewed in this article. Measures to reduce exposure can be divided into organisational/administrative and technical/engineering actions. Both strategies are briefly analysed and the basic principles of the theory of shielding are presented. A definition of shielding effectiveness (SE) is given, and the results from the general Transmission...
This review describes the general provisions of and the philosophy behind European Directive 2004/40/EC and ICNIRP (International Commission on Non-Ionizing Radiation Protection) guidelines. As an example of national legislation on the protection of workers against excessive electromagnetic field exposure, regulations established in Poland are summarized. The problems of a practical implementation...
The aim of this study is to investigate the levels of electric and magnetic power frequency fields at 8 electrical transformation stations in the North-East counties of Romania and to check their compliance with standards Spot measurements were carried out on both electric and magnetic fields under overhead conductors of 110-, 220- and 380-kV installations. The magnetic field levels were several orders...
An overview of quasi-static electromagnetic dosimetry is presented. After an introductive description of quantities and standards and a quick look at experimental and analytical approaches, attention is focused on numerical dosimetry. The process that leads to the calculation of results is analyzed in its basic steps, including the representation of the human body by means of a realistic voxel phantom...
The spectrum and the polarization of the magnetic flux density (B-field) of 6 induction heaters and 1 arc oven were measured by means of a PMM (Italy) spectrum analyser. The spectrum analysis showed that no substantial harmonics were observed while the polarization analysis revealed that the operator’s exposure was non-homogeneous within a distance of 1.5 m from the heater. When the distance was larger,...
Health care staff who operate magnetic resonance imaging (MRI) devices are exposed to a static magnetic field of significant spatial heterogenity always produced by MRI magnets during the whole shift. They can also be exposed to pulses of a time-varying magnetic field (gradient field) present only during patients’ examinations. The level of the workers’ exposure depends both on the type of the magnet...
Retractable type fall arresters are part of the equipment used for protecting people against falls from a height. They are an intermediate part between full body harness worn by a man and the structural anchor at the worksite. The most important task of retractable type fall arresters is to arrest people’s falls and to reduce their harmful consequences. Information received from users as well as laboratories...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.