The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Five 3-MHz Therapeutic Ultrasonic (TUS) devices with their respective transducers were employed to study the relationship between the transducer Effective Radiation Area (ERA) and the area of the thermal image generated by irradiating a thermochromic test body. The resulting relationship was linear, in agreement with previous work.
This paper presents a thermochromic test body to qualitative evaluate the Effective Radiation Area (ERA) of Therapeutic Ultrasound (TUS) devices. The thermal areas produced by three transducers are measured and compared to the ERA of the same transducers measured according to the IEC 61689 standard. A linear relationship was obtained between both kinds of areas suggesting that a quantitative relation...
The present work evaluate the heating pattern of therapeutic ultrasound using immersion technique in a phantom of fat tissue made of silicone in different distances. Five tests were performed in each of six positions: 0, 1, 2, 3, 5 and 10 cm apart from the transducer surface, at 1 MHz, continuous mode and effective intensity 1.05 W·cm−2 for 180s. In the most superficial thermocouple, there was decrease...
The present work describes a method for acquiring thermal images generated by physiotherapeutic ultrasonic beams along a phantom of fat tissue made of PVCP. Five tests were performed in three ultrasound equipments, transducers operating at 1 and 3 MHz and nominal intensity 1.0 W. cm-2, totalizing thirty infrared thermal images that were then evaluated on a PC-like microcomputer. The method seems to...
Perfusion quantification software commonly analyzes log-compressed video images provided by ultrasound systems. Compared to analysis of raw RF signals, errors in perfusion parameter estimates may be introduced, even when proper linearization is applied to reverse the log-compression. In this work, the effects of log-compression, demodulation, scan conversion and 8-bit quantization have been investigated,...