The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Cracking of an oil inlet pipe in an electrohydraulic governing system was detected and analyzed to determine its failure mechanism. Microscopic analysis methods, such as the scanning electron microscopy and energy-dispersive X-ray spectrum, were applied to obtain the effective information. Visual and micro-examination showed that the pipe suffered a brittle cracking at the elbow part. Corrosion pits...