The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The multi-level current reinjection (MLCR) concept produces high quality line current waveforms in current source converters (CSC) by injecting an reinjection current. Two rein-jected waveforms: Symmetrical waveform and Linear waveform are known. In this paper the influence of varying the zero width period (ZWP) of symmetrical waveform on line current harmonics of self-commutated MLCR CSC is studied...
Multi-level Current Reinjection (MLCR) concept adds self commutation capability to thyristors, and produces a high quality line current waveforms and provides reactive power compensation in current source converters (CSC). Multi-level conversion is applied to generate the required optimum linear multilevel injection current which, when reinjected to the ac side, reduces the line current total harmonic...
The 6-pulse controlled rectifier circuit is very well known. For proper operation of the 6-pulse rectifier, it is necessary to synchronise the firing signals with the mains voltage, else the operation of the rectifier is affected. A firing angle controller, without using any phase lock loop (PLL), is described here. This scheme employs the dq-reference frame to estimate the magnitude and phase angle...
Grid connected power electronic converters must be synchronized to the mains voltage by using suitable converter control circuit and gate signals, in order to function correctly. Without proper synchronization, the operation of the converter is adversely affected. This paper proposes a method to synchronize power converters to the mains voltage without using a phase-lock-loop (PLL). This is achieved...
EMI measurement and separation of the Common and the Differential Mode components of noise is necessary to design proper filter to mitigate EMI. It is also important to determine, which component is dominant in a particular frequency range so that the power supply filter may be modified to suit the regulatory limits. Fourier series Analysis is used in this paper to determine the area of dominance...