The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
An experimental study of the effect of flow geometry (circular, rectangular, triangular, and dumb-bell shaped) on the critical heat flux (CHF) was performed using R-134a as a coolant. The CHF is affected by the following geometric parameters: hydraulic-equivalent diameter, heated length, gap size, channel shape, and curvature. It may also be affected by the thermal conductivity of the wall material...