The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
In order to replace the SF6 gas with strong greenhouse effect in the high-voltage switchgear, CO2 has become one of the hotspots. In this paper, LW35-40.5(G)/T2500(3150)-31.5 gas-blast circuit-breaker is used as the research object to study the dielectric recovery characteristics of CO2 gas-blast arc chamber under no-load breaking, so that the theoretical basis for the development of CO2 circuit-breaker...
Manufacturers have paid more and more attention to solid insulation Ring Main Unit (RMU). The usage of RMU is needed more and also the requirement to its performance is higher. In this paper, a 12kV solid insulation RMU has been taken as a research object. Realistic 3-D simulation models were built in Solidworks software. A simplified model of a solid insulation RMS was setup with or without shielding...
In the tendency of high capacity and structure miniaturization, 40.5kV solid insulation vacuum circuit breakers have been widely used in electrical distribution networks. In order to investigate the effect of the grounded shield on insulating performance, the electric field distribution of a solid insulation vacuum circuit breaker was calculated by finite element analysis software. Taking a 40.5kV...
Restrike caused by interrupting capacitor banks with vacuum circuit breakers will lead to severe switching overvoltage, which may cause great damage to power system. Reducing the probability of restrike during capacitive current breaking is the ultimate solution to limit overvoltage. In this paper, a new design of vacuum circuit breaker with a very low probability of restrike is proposed based on...
The objective of this paper is to present a 126-kV/40-kA–2500-A single-break vacuum circuit breaker (VCB) and its type test results based on the IEC 62271-100: 2006 and GB1984-2003 standards. A single-break 126-kV vacuum interrupter (VI), with a pair of 2/3 coil-type contacts, is used in the 126-kV VCB. The external insulation of the VI is provided by at 0.1 MPa. A spring-type operating...
Because of great harmfulness of greenhouse effect, SF6 gas has to be limited, and it is necessary to develop high voltage vacuum circuit breakers to replace SF6 circuit breakers. Current chop is a well-known phenomenon for vacuum interrupters and results in high overvoltage. The chopping current depends not only on material parameters and gap parameters, but also on the parameters of the electrical...