The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
In this paper, an improved control strategy for three-phase inverter is proposed, which ensures three-phase output voltage symmetry under unbalanced grid voltage. Firstly, the positive and negative sequence separation module is used to obtain unbalance output voltage and current during the grid faults. By calculating output power of the inverter, an improved P-ƒ, Q-U and Q-G droop control strategy...
For the islanded microgrid which is connected with nonlinear loads, an effective harmonic sharing method should be designed to guarantee the system stable operation. In this paper, a novel method of virtual impedance and PCC voltage compensation are proposed to achieve the harmonic sharing and voltage quality improvement at the point of common coupling (PCC). The fundamental and each harmonic currents...